Setting up the conference system

Setting up the conference system

Basic information on the set-up of the conference system

Regardless of the number of conference units and the room size, we recommend
the following procedure for setting up the conference system:

Plan the number of conference units required for your conference system.
A total of 400 conference units can be used in a conference system (the
number of ADN C1 chairperson units is limited to 10 max.). Always take the
largest possible number of participants as a starting point.

Plan if simple cabling is sufficient or if you require a redundant ring topology
(see page 5).

If necessary, calculate the number of ADN PS power supplies required (a max.
of 15 ADN PS power supplies can be used in a conference system). 

If necessary, calculate the maximum length of the cabling in order to ensure
that all conference units connected are supplied with sufficient voltage
(see page 7).

Place the ADN CU1 central unit and, if necessary, the ADN PS power supplies in
the electrical equipment room.

Place the conference units at the corresponding seats.

Put out a sufficient number of SDC CBL RJ45 system cables in the required
lengths.

Setting up a small conference system with only the central unit

For a small conference system, you do not require ADN PS power supplies. The
conference units can be directly connected to the ADN CU1 central unit (refer to the
quick guide of the ADN CU1 central unit or to the detailed instruction manual “ADN
Conference System”).

CAUTION

Product damage due to an unsuitable power supply!

If you connect standard network devices with RJ45 plugs (e.g. switches or network
cards) to the connection sockets 

PORT I

 and 

PORT II

, the network devices can be

damaged due to an unsuitable power supply.

Only connect ADN C1 and ADN D1 conference units to the connection sockets

PORT I

 and 

PORT II

KA_ADN-PS_543374_0911_SP13.book  Seite 9  Mittwoch, 31. August 2011  12:23 12

Summary of Contents for ADN PS -

Page 1: ...Quick guide ADN PS Audio Distribution Network...

Page 2: ...verview ADN PS power supply 4 Structuring and controlling the conference system 5 Preparing the ADN PS power supply for use 8 Setting up the conference system 9 Switching the ADN PS power supply on of...

Page 3: ...erence units you require ADN PS power supplies A max of 15 ADN PS power supplies can be used in a conference system When the conference units are connected in simple strings one ADN PS power supply ca...

Page 4: ...pology for conferences with up to 400 conference units ADN PS UK power supply UK version 505547 ADN PS US power supply US version 505548 Number Description Cat No Function Max 400 ADN D1 delegate unit...

Page 5: ...cket output 1 RJ45 for connection of conference units PORT II socket output 2 RJ45 for connection of conference units DATA CU PS input socket RJ45 for connection of ADN CU1 central unit or ADN PS powe...

Page 6: ...ference systems comprising an ADN CU1 central unit and a max of 15 ADN PS power supplies max 400 conference units connected in simple strings or in ring topology per ADN PS power supply 60 70 conferen...

Page 7: ...rence and additional ADN PS power supplies for powering the conference units The conference units are interconnected in cable strings and up to four cable strings can be connected to each ADN PS power...

Page 8: ...e voltage supply of the conference units The ADN Cable Calculator software allows you to calculate the voltage supply on the individual sections of a cable string or cable ring and to plan the structu...

Page 9: ...ature of the individual ADN PS power supplies may drastically increase high mechanical loading may be exerted on e g the housings cables or installation surfaces This can cause material damage and per...

Page 10: ...ference units connected are supplied with sufficient voltage see page 7 Place the ADN CU1 central unit and if necessary the ADN PS power supplies in the electrical equipment room Place the conference...

Page 11: ...the conference units are connected in simple strings one ADN PS power supply can power approx 60 70 conference units Connecting conference units connected in a cable string to the ADN PS power supply...

Page 12: ...tem cables For further information refer to the detailed instruction manual ADN Conference System IN OUT IN OUT IN OUT PORT I PORT II ADN D1 ADN C1 ADN PS CU PS PS PORT I 1 2 PORT II 1 2 DATA 100 240V...

Page 13: ...10 Use a system cable to connect output 1 of the PORT I socket of the ADN PS power supply to the IN socket of the first conference unit Use a system cable to connect the OUT socket of the first confer...

Page 14: ...urther information refer to the detailed instruction manual ADN Conference System IN OUT IN OUT IN OUT PORT I PORT II ADN D1 ADN C1 ADN PS CU PS PS PORT I 1 2 PORT II 1 2 DATA 100 240V 50 60Hz 385W PO...

Page 15: ...tched off To completely switch the ADN CU1 central unit or the ADN PS power supply off Disconnect the mains connector of the ADN CU1 central unit or the mains connector of the ADN PS power supply from...

Page 16: ...central unit and the ADN PS power supplies Clean the air vents on the front back and bottom from time to time with a soft brush or paintbrush in order to avoid dust deposits CAUTION Liquids can damage...

Page 17: ...voltage at RJ45 PORT I II output 1 2 52 8 V Nominal output current at RJ45 PORT I II output 1 2 max 5 25 A in total max 1 75 A per output Output voltage at RJ45 DATA 52 8 V Nominal output current at...

Page 18: ...Sennheiser electronic GmbH Co KG Am Labor 1 30900 Wedemark Germany www sennheiser com Publ 09 11 543374 A01 KA_ADN PS_543374_0911_SP13 book Seite 2 Mittwoch 31 August 2011 12 23 12...

Reviews: