background image

Setting up the conference system

12 | 

ADN PS

Setting up large conference system comprising ADN PS power supplies 
conference units connected in redundant ring topology

In large conference systems with up to 400 conference units, the redundant ring
topology ensures that, should one conference unit or system cable fail or be
manipulated, all other conference units of the cable ring will continue to function
reliably. When the conference units are connected in ring topology, one ADN PS
power supply can power approx. 30-40 conference units.

Connecting conference units

connected in a cable ring to the

ADN PS power supply

The following describes how to connect one cable ring to an ADN PS power supply.
If necessary, repeat these steps for a second cable ring and additional ADN PS
power supplies.

Connect the required number of ADN PS power supplies to the ADN CU1 central
unit (see page 10).

Use a system cable to connect output

1

 of the 

PORT I

 socket of the ADN PS

power supply to the 

IN

socket

 of the first conference unit.

Use a system cable to connect the 

OUT

socket

 of the first conference unit to

the 

IN

socket

 of the second conference unit. 

Repeat these steps for additional conference units.

Use a system cable to connect the 

OUT

socket

 of the last conference unit in

the cable ring to output

2

 of the 

PORT I

 socket of the ADN PS power supply. 

If necessary, repeat all steps for a second cable ring on 

PORT II

 and the

additional ADN PS power supplies.

To ensure full operational reliability in a redundant ring topology, the
hardware of the ADN C1 and ADN D1 has been revised. If you combine
conference units with hardware revision 1 (no marking on the type plate)
and conference units with hardware revision 2 (“

HW: v2

” is printed on the

type plate), fail-safe operation is only possible to a limited extent. 

In a redundant ring topology, only use conference units with hardware
revision 2.

IN    O

UT

6

7

KA_ADN-PS_543374_0911_SP13.book  Seite 12  Mittwoch, 31. August 2011  12:23 12

Summary of Contents for ADN PS -

Page 1: ...Quick guide ADN PS Audio Distribution Network...

Page 2: ...verview ADN PS power supply 4 Structuring and controlling the conference system 5 Preparing the ADN PS power supply for use 8 Setting up the conference system 9 Switching the ADN PS power supply on of...

Page 3: ...erence units you require ADN PS power supplies A max of 15 ADN PS power supplies can be used in a conference system When the conference units are connected in simple strings one ADN PS power supply ca...

Page 4: ...pology for conferences with up to 400 conference units ADN PS UK power supply UK version 505547 ADN PS US power supply US version 505548 Number Description Cat No Function Max 400 ADN D1 delegate unit...

Page 5: ...cket output 1 RJ45 for connection of conference units PORT II socket output 2 RJ45 for connection of conference units DATA CU PS input socket RJ45 for connection of ADN CU1 central unit or ADN PS powe...

Page 6: ...ference systems comprising an ADN CU1 central unit and a max of 15 ADN PS power supplies max 400 conference units connected in simple strings or in ring topology per ADN PS power supply 60 70 conferen...

Page 7: ...rence and additional ADN PS power supplies for powering the conference units The conference units are interconnected in cable strings and up to four cable strings can be connected to each ADN PS power...

Page 8: ...e voltage supply of the conference units The ADN Cable Calculator software allows you to calculate the voltage supply on the individual sections of a cable string or cable ring and to plan the structu...

Page 9: ...ature of the individual ADN PS power supplies may drastically increase high mechanical loading may be exerted on e g the housings cables or installation surfaces This can cause material damage and per...

Page 10: ...ference units connected are supplied with sufficient voltage see page 7 Place the ADN CU1 central unit and if necessary the ADN PS power supplies in the electrical equipment room Place the conference...

Page 11: ...the conference units are connected in simple strings one ADN PS power supply can power approx 60 70 conference units Connecting conference units connected in a cable string to the ADN PS power supply...

Page 12: ...tem cables For further information refer to the detailed instruction manual ADN Conference System IN OUT IN OUT IN OUT PORT I PORT II ADN D1 ADN C1 ADN PS CU PS PS PORT I 1 2 PORT II 1 2 DATA 100 240V...

Page 13: ...10 Use a system cable to connect output 1 of the PORT I socket of the ADN PS power supply to the IN socket of the first conference unit Use a system cable to connect the OUT socket of the first confer...

Page 14: ...urther information refer to the detailed instruction manual ADN Conference System IN OUT IN OUT IN OUT PORT I PORT II ADN D1 ADN C1 ADN PS CU PS PS PORT I 1 2 PORT II 1 2 DATA 100 240V 50 60Hz 385W PO...

Page 15: ...tched off To completely switch the ADN CU1 central unit or the ADN PS power supply off Disconnect the mains connector of the ADN CU1 central unit or the mains connector of the ADN PS power supply from...

Page 16: ...central unit and the ADN PS power supplies Clean the air vents on the front back and bottom from time to time with a soft brush or paintbrush in order to avoid dust deposits CAUTION Liquids can damage...

Page 17: ...voltage at RJ45 PORT I II output 1 2 52 8 V Nominal output current at RJ45 PORT I II output 1 2 max 5 25 A in total max 1 75 A per output Output voltage at RJ45 DATA 52 8 V Nominal output current at...

Page 18: ...Sennheiser electronic GmbH Co KG Am Labor 1 30900 Wedemark Germany www sennheiser com Publ 09 11 543374 A01 KA_ADN PS_543374_0911_SP13 book Seite 2 Mittwoch 31 August 2011 12 23 12...