background image

×

If out of tolerance, rework 

from step 【5】

Clean bare fiber 

with a lint-free 

Gauze Pad 

moistened with 

pure Alcohol

【13】Remove the wedge

【1】Preparing connector

【15】Remove connector

【14】Open the cover

【16】Fitting the boot

【5】Removing fiber jacket 

【2】Setting connector  

Bend fiber several times 

by moving it with your 

finger back and forth.

If fiber breaks, 

please start with 

a new fiber from 

step【5】

±30°

degree

up

left

right

down

!

【9】The fiber cleaver

【10】Fiber length check

【11】Inserting fiber

Be sure to wear
Safety Glasses

【4】Install boot

【6】Cleaning bare fiber【7】Screening fiber

Length of 

bare fiber: 

9-11mm

Be careful not to hit 

the edge of  fiber

!

Click!

13±0.2 mm

!

3】

Preparing the fiber holder

Set  circular groove of connector 

tightly onto semicircular ridge of “U” 

shaped shelf of Jig.

Cover 1

Cover 2

Cover 3

Open covers 1,2, and 3 before using the 

holder. Make sure the guide is not visible from 

the rear of the fiber holder. If the guide is 

visible push the back-end into the fiber holder.

Correct

Incorrect

Fiber front 

edge location 

(Within groove 

range)

Location for 

the fiber jacket.

【12】Unlock the lever

“U” shaped 

area must

be free of 

debris/dust.

Click!

Attention

!

Open cover 2

【8】

Setting fiber on the fiber holder

onto fiber

Guide

wedge

connector

3.Set the fiber 

holder tightly

4.Push the 

cover of 

the cleaver

U-groove

Finished product

Use a visible light 
source to test 
connection

Not following this step will cause an air 

gap between fibers creating high 

insertion loss

!

Be sure there is no space 

between the wedge and 

connector, if there is, push 

the wedge and connector 

together to realign.

Remove fiber jacket, using 

the fiber jacket remover

Remove 30 

to 35 mm of
900 µm jacket using 

jacket remover

Length of 

900 µm fiber 

jacket is within 2mm

Setting fiber on the 

fiber holder

Set the fiber along the groove 

tightly before closing covers 1 

and 2

After closing 

covers 1 and 2 

close cover 3

3

2.Set  the 

fiber holder 

to the 

cleaver

1.Set the 

cleaver 

for cutting

Set the fiber holder to the guide rail. Be 

sure the fiber aligns with the U-groove

Slide the fiber holder 

slowly until it stops 

2

hold the sides of the 

fiber holder so that 

the fiber moves freely

Insert  until 

clicking sound 

is heard 

Small amount of 

bending is normal

Not following this step 

correctly can cause 

damages to the 

fiber ends

open lock lever

Push the arms 

to remove the 

wedge

Open covers 1 and 3

3

(no visible light)

Good connection

Bad connection

(visible light)

XP Fit Plus LC 900 µm
Field Installable Connector

Instruction Manual (ETP-1108-001-01)