Step 1: Install and configure TempTrackr™ Wireless 

Interrogation Software

Insert Interrogation Software CD into PC/Laptop drive.  The 

installation process should begin automatically.  If this does not 

happen, please access the CD drive using Windows Explorer and 

double-click the “setup.exe” icon as shown in Figure 1. 

Figure 2: Accessing the setup.exe icon via Windows Explorer

Step 1: 

continued...

Please use the InstallShield Wizard, shown in Figure 2, to complete 

the installation process. Successful installation will result in the 

creation of a directory called TempTrackr in the path C:\Program 

Files\Sengenuity\TempTrackr. 

Start the Software from the Windows Start Menu or by double-

clicking the WSR-T2 icon from the directory in which the software 

has been installed.

Figure 1: InstallShield Window for TempTrackr™

Step 1: 

continued...

The  software  will  apply  regulatory  restrictions  based  on  your 

geographic  region.    The  FCC  complaint  version  of  the  kit  will 

include  software  that  conforms  to  FCC  requirements.    The  CE 

compliant version of the kit will include software that conforms to 

CE requirements:

FCC  requirements  impose  the  following  restrictions  on  the 

• 

reader:

The reader will read sensors only once every 30s.

• 

The reader will only make use of one antenna.  The other 

• 

two  antenna  ports  are  deactivated  on  FCC  compliant 

readers.

CE requirements restrict the reader to only operate in the 433 

• 

MHz ISM-Band.  This means that you will only be able to read 
one sensor with a CE compliant reader.

Figure 3: Regional setting for regulatory compliance

Summary of Contents for TempTrackr

Page 1: ...on Software Please contact SenGenuity if any item is either missing or damaged The wireless interrogation unit needs to be powered by a 5V 5 DC power supply All temperature sensors are interrogated by...

Page 2: ...ngenuity TempTrackr Start the Software from the Windows Start Menu or by double clicking the WSR T2 icon from the directory in which the software has been installed Figure 1 InstallShield Window for T...

Page 3: ...ued Connect the Wireless Interrogation Unit to a power supply 5V 5 DC 350mA as shown in Figure 6 You can now connect the RS232 RS485 cable to your PC laptop Step 2 Step 2 Setup and connect wireless in...

Page 4: ...t should be followed when locating the sensors The minimum distance between two sensors must be 4 inches 10 cm The minimum distance between any given sensor and the interrogation antenna must be 12 in...

Page 5: ...eaders Step 3 continued Select Calibrate from the Sensors Menu to obtain the Calibration Screen Sensors are identified by model numbers that reflect nominal the frequency of each sensor Since the six...

Page 6: ...ise the calibration will be lost if the reader is powered off Press Test VALUE_INTER again Figure 13 shows the results of a successful calibration Figure 13 Calibration procedure FCC version complete...

Page 7: ...nd found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a reside...

Page 8: ...pas l intensit n cessaire l tablissement d une communication satisfaisante Le pr sent metteur radio identifier le dispositif par son num ro de certification ou son num ro de mod le s il fait partie du...

Reviews: