background image

7/8

ELECTRICAL CONNECTIONS

Power supply and Modbus interface are available using the Seneca DIN rail bus, via the IDC10 rear connector, or 

the Z-PC-DINAL-17.5 accessory.

RS485 GND

 

RS485 A

 

RS485 B

 

Power Supply AC / +

 

Power Supply  AC / -

IDC 10

Back connector (IDC 10)

The illustration shows the meanings of the various 

IDC10 connector pins if signals are to be sent via 

them directly.

Power Supply AC

Ground

Power Supply AC

GNDSHLDG

ND

CANL / B

CANL / A

DIP SWITCH

(1230 Ohm terminator)

Z-PC-DINAL2-17.5 accessory use

If the Z-PC-DINAL2-17.5 accessory is used, signals 

can be sent via terminal boards. The illustration 

shows the meaning of the various terminals and DIP-

switch position (found in all supports for the DIN rail 

listed in Accessories) for the termination of the CAN 

network (not used for the Modbus network). GNDSH-

LD: 

Connection cable signal protection shield (recom-

mended).

Retransmitted input/output

The module accepts an input voltage up to 500 Vac maximum. Provide the input voltage to terminals 10 and 12 

and connect terminals 7 and 9 to the load to be analyzed.

MAX

5 A rms

MAX 

500 V

AC

7

9

10

12

LINE IN

LINE OUT

Z203-2

LINE

LOAD

Analogue output

The module provides a voltage output (0 - 10 Vac, 0 - 5 

Vac) or current (0 - 20 mA, 4 - 20 mA).

For the electrical connections, we advise you to use 

screened cables. 

NB: there is no isolation between RS485 and retransmit-

ted output.

2 3

5

5

6

4

+

+

Digital output

The module provides a digital output: each pulse (dura-

tion: 200 ms) corresponds to a certain number of incre-

ments of the energy count (see the Digital Output Ratio 

register). Imax=V/R=50 mA

+

6

1

+

-

I

R

V

EXAMPLE OF CONNECTION WITH EXTERNAL TA (in this case, configure the Z203-2 using the software 

and NOT the dip-switches)

F

230 Vac

N

P1/K

P2/L

S1/K

S2/L

TA

Z203 -2

N.C.

7 9

10 12

LOAD

MODULE SUPPLY

Voltage output

Current output

Digital output 

Summary of Contents for Z203-2

Page 1: ...single phase network analyzer SENECA s r l Via Austria 26 35127 PADOVA ITALY Tel 39 049 8705355 8705359 Fax 39 049 8706287 For manuals in other languages and configuration software visit www seneca i...

Page 2: ...seneca it products z203 2 Important Obstructing ventilation slots with any object is prohibited Installing the module next to devices that generate heat is prohibited Electrical and electronic waste...

Page 3: ...factor 3 Maximum current 15 A Frequency from 35 to 75 Hz Class Base Prec Voltmeter 0 5 Ammeter 0 5 Wattmeter 0 5 active power ANALOGUE OUTPUT Voltage output 0 10 Vdc 0 5 Vdc minimum load resistance 2...

Page 4: ...ional to the full scale value of the measured quantity For example if the retransmitted signal is in current 4 20 mA and the quantity to retransmit the voltage Vrms we will have that 4 mA will corresp...

Page 5: ...BAUD RATE 19200 38400 57600 1 ADDRESS 2 63 From EEPROM 5 8 DIP Switch status SW2 POSITION DESCRIPTION 1 2 3 4 5 6 7 8 Network frequency 50 Hz NETWORK NOMINAL FREQUENCY SELECTION 50 60 Hz Network frequ...