DRIVER INSTALLATION

The user is provided with a CD containing the instrument driver.
In this section we will describe in detail the driver installation procedure. 
It should be noted that the installation in Linux environments (with Kernel 3.0.0-19 or later) is automatic and does 
not require the driver CD. The standard serial port of the PC with which the device is identified is the following: 
/dev/ttyUSB0.
As for Windows operating systems, it is important to stress that the procedure consists of two distinct phases, 
equally important for the final use of the instrument. In the first part the driver of the actual serial converter will be 
installed. Through the second phase the virtual driver will be installed which will allow the use of the peripheral as 
a standard serial port of the operating system.
If you are using Windows 7, these two phases are identical and are followed step by step, while for other versions 
of Windows the second part is automatically managed by the operating system without further dialogue with the 
user. Below is the installation procedure for Windows 7.

DRIVER INSTALLATION WITH WINDOWS 7:

Connect the instrument to the PC already switched on, so that the operating system can detect the presence of 
the device automatically. As soon as the operating system detects the presence of the converter, the installation 
will begin and the following messages will be displayed:

FIG. 1

FIG. 2

Summary of Contents for S107USB

Page 1: ...us serial converter SENECA s r l Via Austria 26 35127 PADOVA ITALY Tel 39 049 8705355 8705359 Fax 39 049 8706287 For manuals in other languages and configuration software visit www seneca it products...

Page 2: ...eck that the PC s USB socket provides for the supply of the 5 V needed to power the instrument The Rx led remains on continuously Check that the RS485 cables have not been swapped The received data is...

Page 3: ...ed by the Manufacturer The product is sensitive to electro static discharges Take appropriate measures during any operation TECHNICAL SPECIFICATIONS STANDARDS EN61000 6 4 Electromagnetic emissions ind...

Page 4: ...regard to the S107USB instrument there are no particular precautions to follow except that of using a shielded cable for the RS485 lines for long connections or connections in noisy environments pleas...

Page 5: ...jumper between terminals T1 and T2 the terminator of the RS485 line is enabled We also recommend to use a shielded cable for the RS485 line in particular if long connections are to be made or in nois...

Page 6: ...the actual serial converter will be installed Through the second phase the virtual driver will be installed which will allow the use of the peripheral as a standard serial port of the operating system...

Page 7: ...matic procedure or by connecting http www ftdichip com Drivers VCP htm For the automatic proce dure configure as in Fig 3 On the next screen proceed as follows At the end of the search for the driver...

Page 8: ...nd reproduction are prohibited unless authorised The con tent of this document corresponds to the described products and technologies Stated data may be modified or supplemented for technical and or s...

Reviews: