(SENEC.Home) to be incorporated when an electric
vehicle is being charged, for example.
Please observe the points below for trouble-free
installation and commissioning.
3.1
Prerequisites
•
At least two Wallboxes
with local load
management.
•
At least one Wallbox and an external control
system with external load management.
•
Up to 16 Wallboxes with local load management.
•
Up to four Wallboxes with connection to a SENEC
storage system with external load management.
•
One hybrid/electric vehicle per Wallbox.
•
Energy supply at least 6 A per Wallbox (in case of
overloading, ongoing charging processes will be
completed first).
i
To avoid single-phase load peaks, connect the
devices with an alternating phase sequence.
•
First Wallbox: L1, L2, L3.
•
Second Wallbox: L2, L3, L1.
•
Third Wallbox: L3, L1, L2.
•
Fourth Wallbox: L1, L2, L3 again, etc.
3.2
Bus topology
Prerequisites:
•
Bus system: RS485 fieldbus
•
Protocol: Modbus RTU
• The leader distributes the total current in the
system.
•
A charging current (default: 6 A) is configured for
each Wallbox. Set the required charging current.
•
The follower Wallboxes revert to standby state
when not in use.
•
Communication between the follower Wallbox
and leader Wallbox is required in order to start
the charging process.
Local load management:
•
One Wallbox as the leader and at least one or up
to 15 Wallboxes as followers.
•
The physical position of the Wallbox (leader) is
freely selectable.
External load management:
•
External control system (e.g. HEMS) which is
configured as the leader and at least one or up to
16 Wallboxes as followers.
3.3
Check-list for local load
management
•
Wire the power supply and the bus system so as
to avoid single-phase load peaks.
•
Select the leader Wallbox.
•
Set the number of follower Wallboxes in the
leader Wallbox.
•
Set the maximum system current in the leader
Wallbox.
•
Set the maximum and minimum individual
charging currents in each Wallbox.
•
Set the bus ID in each follower Wallbox.
•
Activate the bus terminating resistor in the first
and last Wallboxes.
•
Configure the optional blocking function in the
leader Wallbox.
3.4
Check-list for external load
management
•
Wire the power supply and the bus system so as
to avoid single-phase load peaks.
•
Configure the external control system (following
the manufacturer’s instructions).
•
Set each Wallbox as a follower Wallbox.
•
Set the bus ID in each Wallbox.
•
Set the maximum and minimum individual
charging currents in each Wallbox.
•
Activate the bus terminating resistor in the
external control system and the last Wallbox.
4.
Configuration of the Wallboxes
The individual Wallboxes must be pre-configured
using rotary switches and micro switches to operate
the integrated network of Wallboxes
. All
rotary switches and micro switches are initially set
to OFF. The configuration differs in some cases,
depending on the local or external load manage
-
ment mode.
Mode-independent switch functions:
S1: rotary switch S1 is used to set the maximum
charging current of 6 A to 16 A per Wallbox
S3: configuration of minimum charging current
S6: bus terminating resistor On/Off
Switch functions in local load management mode:
S2: setting of maximum system current (only in
leader Wallbox)
S4: in leader Wallbox: setting of the number of
followers
S4: In follower Wallbox: setting of the respective
bus ID
S5: setting of leader or follower, front illumination
and blocking
Summary of Contents for Wallbox pro s
Page 4: ...4 VI SENEC Wallbox pro s max 10mm max 10mm M 12 Nm V 210mm 105mm 260mm 16kg 1000 1100mm...
Page 6: ...6 VIII...
Page 8: ...8 X 5 3 7 3mm max 2 x 0 5mm 100mm 30mm 6mm Chapter 1 8 3...
Page 9: ...9 XI SENEC Wallbox pro s Chapter 2 2...
Page 10: ...10 XII Chapter 2 2 2 SENEC Wallbox pro s t 5min S5 1 OFF ON S2 S6 S3 S4 S5 S5 S5...
Page 11: ...11 t 5min 1 2 3 4 5 6 7 XIII XIV ON Chapter 2 2 2 SENEC Wallbox pro s SENEC Wallbox pro s...
Page 12: ...12 XV Chapter 2 2 1 XVI 3 4 1 2 SENEC Wallbox pro s Chapter 1 7...
Page 13: ...13 XVI SENEC Wallbox pro s 1 2 Chapter 1 8...
Page 50: ...50 VI CAT6a max 500m 15mm 60mm 70mm 8mm VII...
Page 51: ...51 VIII 3 5 2 1 4...
Page 53: ...53 3 5 2 1 4 XI...
Page 55: ...55 XIV S2 S6 S1 S3 S4 S5...