DMG 3200/3100/3000 – User Manual
Page 47 (306)
5.2.2 Input Service Filtering and Analysis
It is possible to apply filters on information displayed in the GUI. Clicking on
view
in the
Service
column for a selected multicast, results in only services associated with this multicast being
displayed. Clicking on one of the listed services will display more detailed information about the
different PIDs like PMT, PCR, video, audio, etc.
Click on
view
in the
PID
column for ASI inputs will display only PIDs associated with the
selected input. Simply choose any PID to obtain more detailed information.
To access detailed PSI/SI analysis of the input services, click the respective service in the lower
pane. The detailed analysis result will appear next to it, on the right.
Figure 5.4 - Detailed PSI/SI Analysis of Input Services
The Audio language descriptor is decoded. In Figure 5.4, the audio is listed as
dan
, ie Danish.
However, if no language descriptor is present the unit will auto-generate a descriptor for internal
usage and they will be named A01, A02, etc.
Details of the PSI/SI analysis are not 100% DVB compliant, but it does include
the most commonly used tables and descriptors.
Summary of Contents for DMG 3000
Page 65: ...DMG 3200 3100 3000 User Manual Page 65 306 Figure 5 24 QAM Status View...
Page 69: ...DMG 3200 3100 3000 User Manual Page 69 306 Figure 5 27 COFDM Status View...
Page 74: ...DMG 3200 3100 3000 User Manual Page 74 306 Figure 5 29 Edit IP Port...
Page 119: ...DMG 3200 3100 3000 User Manual Page 119 306 Figure 6 28 Adding an EIS...
Page 167: ...DMG 3200 3100 3000 User Manual Page 167 306 Figure 7 57 Packets dropped in Output View...
Page 277: ...DMG 3200 3100 3000 User Manual Page 277 306 Figure 10 28 Encoder redundancy topology...
Page 303: ...DMG 3200 3100 3000 User Manual Page 303 306 Figure 12 4 DIP switch ON DMG 3200...