Figure 6.19- Adding an ECM Generator
The following information is displayed:
Input
Logical port representing the connection to the ECMG – assigned automatically.
This number is used internally as well as for generating alarms.
Channel
The SimulCrypt Channel ID used for the CA system
Name
For reference in the GUI only
IP
IP address of the ECMG
Port
TCP port of the ECMG
CAS ID
CA vendor specific ID
Sub ID
CA vendor specific sub ID
State
Status of ECMG connection, either
OPEN
or
NOT CONNECTED
.
To change an, ECMG channel connection click on the existing ECMG entry and enter the new
configuration.
It is possible to have several ECMG connections simultaneously but the CAS ID
has to be uniquely defined. If the same CAS ID is used, a real SimulCrypt will
not work as the CA Descriptor in the PMT will be identical for both ECMs. In this
case, private data must be used by STBs to distinguish ECMs.
Summary of Contents for DMG 3000
Page 65: ...DMG 3200 3100 3000 User Manual Page 65 306 Figure 5 24 QAM Status View...
Page 69: ...DMG 3200 3100 3000 User Manual Page 69 306 Figure 5 27 COFDM Status View...
Page 74: ...DMG 3200 3100 3000 User Manual Page 74 306 Figure 5 29 Edit IP Port...
Page 119: ...DMG 3200 3100 3000 User Manual Page 119 306 Figure 6 28 Adding an EIS...
Page 167: ...DMG 3200 3100 3000 User Manual Page 167 306 Figure 7 57 Packets dropped in Output View...
Page 277: ...DMG 3200 3100 3000 User Manual Page 277 306 Figure 10 28 Encoder redundancy topology...
Page 303: ...DMG 3200 3100 3000 User Manual Page 303 306 Figure 12 4 DIP switch ON DMG 3200...