Cleaning the vacuum cleaner.
only use a soft dry (or dampened) cloth for cleaning the vacuum cleaner. Do not use any aggressive
cleaning agents or solvents!
TroubleshooTInG
Before you decide to contact an authorised service centre, please read these following tips in the
troubleshooting chart:
problem
possible cause
possible solution
the motor will not start
the power cord is not inserted
correctly in the power socket
Insert the plug firmly into the
power socket
the power socket is damaged
Inspect the power socket
the vacuum cleaner is not
switched on
turn on the appliance
suction power is insufficient
the appliance is clogged
remove the blockage or foreign
object
the dust filter needs cleaning
clean the dust filter
the dust container a
4
is
inserted in the wrong position
close the dust container a
4
the filter is clogged
clean the filter
the power cord is not wound in
completely
the power cord may have
slipped down from the
winding pulley during winding.
hold the power cord during the
winding. apply slight tension
(by pulling the power cord
back) to the power cord during
the winding process
the power cord cannot be pulled
out
the power cord is wound up
incorrectly
press the cord winding button
a
7
and try to rewind the
power cord again
the speed control is not
working.
the appliance is out of order
arrange the appliance to be
repaired (only by a professional)
the power cord starts to wind in
when you do not want it to
the winding mechanism is out
of order
arrange the appliance to be
repaired (only by a professional)
the dust container a
4
cannot
be closed
the dust filter is not in the
correct
position
reinstall and secure the filter in
position and try again