EN-12
Electrical connection
NOTE:
This unit must be installed in accordance with national regulations.
This unit must not be installed in the laundry room.
This unit must be installed at a min. height of 2.3 m above the floor.
This unit must be installed so that a power socket is accessible.
According to national regulations, models with a cooling capacity above 4600 W (17000 BTU/h) must
have disconnection built in all poles of the fixed connection, with a minimum 3 mm space and a residual
current device in all poles with a rated current minimum of 10 mA.
EXTERIOR UNIT INSTALLATION
Electrical connection
Exterior unit terminal
Connecting cable
INSTALLATION INSTRUCTIONS
Wiring for Model above 6000 W (Model above 21000 BTU/h)
Screw
Interior unit terminal
Connecting cable
Terminal board
Fix the cable wire
with anchor cable
Piping cover
Maintenance
board
Outdoor pipe support
(Outdoor pipe supportis not required
when leading the cable wire from other places).
Maintenance
board
Back wiring
Right wiring
Piping cover Ejecting hole
Sponge
Piping cover