SWITCH BANK 2
Computer Output Enable
SWITCH POSITION
OPEN
CLOSED
S2:1
Computer Output Off
Computer Output On
s2:2
Software Handshake Off
Software Handshake On
Computer Transmission Data Format
S2:3
S2:4
S2:5
FORMAT
OPEN
OPEN
OPEN
7 data bits - Even Parity - 2 Stop Bits
OPEN
OPEN
CLOSED
7 data bits - Odd Parity - 2 Stop Bits
OPEN
CLOSED
OPEN
7 data bits - Even Parity - 1 Stop Bits
OPEN
CLOSED
CLOSED
7 data bits - odd Parity - 1 Stop Bits
CLOSED
OPEN
OPEN
8 data bits - No Parity - 2 Stop Bits
CLOSED
OPEN
CLOSED
8 data bits - No Parity - 1 Stop Bits
CLOSED
CLOSED
OPEN
8 data bits - Even parity - 1 Stop Bits
CLOSED
CLOSED
CLOSED
8 data bits - Odd Parity - 1 Stop Bits
Computer Transmission Baud Rate
S2:6
S2:7
S2:8
BAUD RATE
OPEN
OPEN
OPEN
76800*
CLOSED
OPEN
OPEN
38400
OPEN
CLOSED
OPEN
19200
CLOSED
CLOSED
OPEN
9600
OPEN
OPEN
CLOSED
4800
CLOSED
OPEN
CLOSED
2400
OPEN
CLOSED
CLOSED
1200
CLOSED
CLOSED
CLOSED
300
*NOTE:
Sencon do not guarantee operation at this speed.
Summary of Contents for SI9500