53
ProBee-ZS10 User Guide Rev.1.2.0
ATZ<CR>
# Apply the change
OK
# Response
AT+NWKKEY=0<CR>
# set the 128-bit network key (random key)
OK
# Response
AT+UPDATEKEY<CR>
# update the changed network key
OK
# Response
6.4
UART Settings
AT+BAUDRATE=115200<CR>
# set baud rate (115,200bps)
OK
# Response
AT+DATABIT=8<CR>
# set data bit (8bit)
OK
# Response
AT+PARITY=0<CR>
# set parity (none)
OK
# Response
AT+STOPBIT=1<CR>
# set stop bit (1bit)
OK
# Response
AT+FLOWCTRL=2<CR>
# set flow control (hardware)
OK
# Response
ATZ<CR>
# Apply the change
OK
# Response
6.5
Firmware Upload
6.5.1
Local Node
# enter the bootloader menu for uploading firmware. Note that UART of local
node should be set to 115200-8-N-1-N.
AT+BOOTLOAD<CR>
Press Enter…
EM250 Bootloader v20 b09
1. upload ebl
2. run
3. ebl info
BL >
# press “1” and upload ebl file by X-modem
begin upload
CCCCCCCCCCCCC
Serial upload complete
# press “2” or reset after upload is done