![Sena ProBee-ZU10 User Manual Download Page 43](http://html1.mh-extra.com/html/sena/probee-zu10/probee-zu10_user-manual_1237629043.webp)
43
ProBee-ZS10 User Guide Rev.1.2.0
5.4.6
AT+STACK or AT+ZS
Description
Get/Set the ZigBee stack profile value. This value must be set the same on all devices
that should join the same network. (0: Network specific, 1: ZigBee, 2: ZigBee Pro)
Execute
AT+STACK?<CR>
AT+STACK=<value><CR>
Response
<value><CR>
OK<CR>
OK<CR> or ERROR<CR>
Default
0
Range
0 - 2
5.4.7
AT+NODENAME or AT+NN
Description
Get/Set the node name. It can be used to make a clear distinction role or functionality
of local node from others.
Execute
AT+NODENAME?<CR>
AT+NODENAME=<value><CR>
Response
<value><CR>
OK<CR>
OK<CR> or ERROR<CR>
Default
ProBee-ZU
Range
Up to 16 characters
5.5
Network Formation and Join
5.5.1
AT+ASCAN or AT+AS
Description
Perform a scanning for existing network. It can take up to 5 seconds.
(
CAUTION: It is possible to cause a link error if a node is a parent of an end-device.
)
Execute
AT+ASCAN<CR>
AT+ASCAN=<channel mask><CR>
Response
<channel>|<PAN ID>|<EPID>|<joinable>|<stack profile>
List of the existing networks
…
OK<CR>
5.5.2
AT+ESCAN or AT+ES
Description
Perform a scanning for energy level of all channels. It can be used to avoid
interference. It can take up to 5 seconds. (
CAUTION: It is possible to cause a link error
if a node is a parent of an end-device.
)
Execute
AT+ESCAN<CR>
AT+ESCAN=<channel mask><CR>
Response
<channel>|<RSSI >
List of the RSSI for each channel
…
OK<CR>
5.5.3
AT+DSCAN or AT+DS
Description
Perform a scanning for existing nodes in the current network. A coordinator or router
can have children nodes and they are presented by “CLDn”. It can be possible to place