![Sena ProBee-ZU10 User Manual Download Page 15](http://html1.mh-extra.com/html/sena/probee-zu10/probee-zu10_user-manual_1237629015.webp)
15
ProBee-ZS10 User Guide Rev.1.2.0
Figure 2-6 ProBee Manager Main Window
Clicking ‘Reboot’ button reboots the local node. Users can reload and refresh the recent configuration of
the local node at ProBee manager by clicking ‘Reload’ button. ‘Configuration’ tab and ‘Firmware Update’
tab can help move to the ‘Configuration’ screen and the ‘Firmware Upgrade’ screen.
2.4.2
Configuration
The Configuration Pane appears when the ‘Configuration’ tab is selected.
To change configuration, users need to find and modify the property and then apply changes. The
properties are categorized according to the function. Selecting a category unfolds or folds the property list.
The name, the current value and the description of the property are shown at the right of the configuration
pane by selecting a property in the property list. It is possible to edit and save the current value of editable
property. Whenever property is modified, it is necessary to save the change by clicking the ‘Save’ button