background image

Press this key to switch the AUTO/MUL counting mode.

Press this key to turn on/off the UV detection.

Press this key to turn on/off the UV detection.

1.Press this key to turn on/off the accumulation function.
2.In the sensitivity level setting, press this key to turn to the previous page.

1.In the BATCH mode, short press this key can increase the batch number one by one.
2.Long press this key, the batch number can be increased continuously, batch rang is 1-100.
1.In the BATCH mode, short press this key can decrease the batch number one by one.
2.Long press this key, the batch number can be decreased continuously, batch rang is 100-1.

1.Press this key can turn on the BATCH function, if press it again, the user can select among

100, 50, 20,

10, off

.

2.In the sensitivity level setting, press this key to go to the next page.
1.Press this key can clear all the fault message, then keeping counting.

2.In the sensitivity level setting, press this key to save and exit.
3.Long press this key for 3 seconds, after hearing the

beep

sound, then the machine is restored to the

factory setting.

5.3 The introduction of the side display panel and the key function

Key

Function

Side display

1.Press this key can clear all the fault message, then keeping

counting.

2.In the sensitivity level setting, press this key to save and exit.
3.Long press this key for 3 seconds, after hearing the

beep

sound, then the machine is restored to the factory

setting.

Press this key to turn on/off the accumulation function.

Press this key to turn on/off the UV, MG detection.

1.Press this key can clear all the fault message, then keeping

counting.

2.In the sensitivity level setting, press this key to save and exit.

Summary of Contents for ST-2620

Page 1: ...BILL COUNTER OPERATION MANUAL BILL COUNTER OPERATION MANUAL...

Page 2: ...solutions 4 The instruction of the main parts 5 The introduction of the display and keys 6 The introduction of the parameter setting 7 Restore to the factory setting 8 Feeding clearance adjustment 9 P...

Page 3: ...or Fault Problem with the counting sensor Clean or replace the counting sensor Problem with the relative circuit of the counting sensor in the main board Replace the main board or replace the left rig...

Page 4: ...ous note detected by MG detection Remove the suspicious note from the stacker press RESET to continue MG sensitivity level is too high Decrease the MG sensitivity level DBL Double note detected by the...

Page 5: ...ing platform 6 reset sensor 1 hopper fixing screw External display optional 2 power socket 3 power switch 4 USB upgrade port 5 external display port 5 The introduction of the display and keys 5 1 The...

Page 6: ...10 off 2 In the sensitivity level setting press this key to go to the next page 1 Press this key can clear all the fault message then keeping counting 2 In the sensitivity level setting press this key...

Page 7: ...s medium adjustment 2 is the senior adjustment the default is 1 6 1 6Standby Time the time of the LCD background automatically off the default is 3 minutes 6 1 7Break Time the time to stop counting Th...

Page 8: ...1 7 Restore to the factory setting Press UV MG RESET at the same time meanwhile turning on the machine after hearing beep sound the machine is restoreto the factory setting 8 Feeding clearance adjust...

Page 9: ...using the machine or it will lead to some danger and fault Avoid exposing the product to the sunlight The product should have well earthing performance The product may affected by the wireless device...

Page 10: ...gs covering the sensor it will lead to the fault when the machine is working The user should clean the machine after using For example if there is some pieces of paper dust or something else covering...

Reviews: