background image

4.The instruction of the main parts

1.counting
guide

1.start sensor

2.handle

2.banknote
feeding wheel

3.main display
assembly

3.UV

light

assembly

4.side display

4.banknote
transporting
wheel

5.banknote
receiving wheel

5.counting tube
frame assembly

6.transporting
platform

6.reset sensor

1.hopper fixing
screw

External display
(optional)

2.power socket

3.power switch

4.USB upgrade
port
5.external
display port

5.The introduction of the display and keys

5.1 The diagram of the main display and the keys

5.2 The introduction of the key function

introduction

Keys

Function

Press this key to turn on/off the denomination clearance function(based on the first counting note).

Press this key to turn on/off the mix value counting.

Summary of Contents for ST-2620

Page 1: ...BILL COUNTER OPERATION MANUAL BILL COUNTER OPERATION MANUAL...

Page 2: ...solutions 4 The instruction of the main parts 5 The introduction of the display and keys 6 The introduction of the parameter setting 7 Restore to the factory setting 8 Feeding clearance adjustment 9 P...

Page 3: ...or Fault Problem with the counting sensor Clean or replace the counting sensor Problem with the relative circuit of the counting sensor in the main board Replace the main board or replace the left rig...

Page 4: ...ous note detected by MG detection Remove the suspicious note from the stacker press RESET to continue MG sensitivity level is too high Decrease the MG sensitivity level DBL Double note detected by the...

Page 5: ...ing platform 6 reset sensor 1 hopper fixing screw External display optional 2 power socket 3 power switch 4 USB upgrade port 5 external display port 5 The introduction of the display and keys 5 1 The...

Page 6: ...10 off 2 In the sensitivity level setting press this key to go to the next page 1 Press this key can clear all the fault message then keeping counting 2 In the sensitivity level setting press this key...

Page 7: ...s medium adjustment 2 is the senior adjustment the default is 1 6 1 6Standby Time the time of the LCD background automatically off the default is 3 minutes 6 1 7Break Time the time to stop counting Th...

Page 8: ...1 7 Restore to the factory setting Press UV MG RESET at the same time meanwhile turning on the machine after hearing beep sound the machine is restoreto the factory setting 8 Feeding clearance adjust...

Page 9: ...using the machine or it will lead to some danger and fault Avoid exposing the product to the sunlight The product should have well earthing performance The product may affected by the wireless device...

Page 10: ...gs covering the sensor it will lead to the fault when the machine is working The user should clean the machine after using For example if there is some pieces of paper dust or something else covering...