Model 0205NANO Operation and Maintenance Manual
SEM | www.semshred.com
7
After Clearing Jam:
• Close unjam door.
• Re-install unjam door screw.
• Plug power cord into unit.
Power Saver Mode
If the unit is not used and the LCD interface display is untouched for several minutes,
the unit will go into low power mode and the display will revert to the SEM splash
screen with a dimmed screen. If the unit is further untouched for several more minutes,
the screen will turn fully black. In either mode the unit may be put back into full power
mode by simply pressing anywhere on the display, activating any of its photo-sensors,
or opening and closing the door.
Maintenance
Waste Bin Full
If the unit becomes full of waste, the
FULL
indicator will appear.
Remove the waste bin bag and install a new one.
Overheat Sensor
The unit is equipped with a thermal switch for safety to ensure
that the motor does not overheat. If the unit is run continuously
for longer than one hour, at some point the switch will engage and
disallow the unit to activate until the temperature has dropped to
safe levels. If this occurs, the
HOT
indicator will appear and the user
must wait for it to automatically reset.
Service Needed Symbol
If the unit encounters many errors or an unsafe condition is
detected, the
SERVICE NEEDED
screen and symbol is displayed. If
this occurs, please contact SEM customer support.
Important
: If the
SERVICE NEEDED
symbol is displayed, there will
be a number displayed along with it. Please write down this number
as it will help identify the cause of the fault.
Summary of Contents for 0205NANO