![Selve iveo Heat Connect Adjustment Instructions Manual Download Page 24](http://html1.mh-extra.com/html/selve/iveo-heat-connect/iveo-heat-connect_adjustment-instructions-manual_1237279024.webp)
iveo Heat Connect
2015-May, 06 – Rev_00
24/36
12.
Repairs
Send the
iveo Heat Connect
to the manufacturer for repair.
13.
Disassembly and disposal
Power down the
iveo Heat
Connect
for dismounting.
Take safety measures against inadvertent activation.
Observe the WEEE directive (Waste of Electrical and Electronic Equipment; German: Elektro-
und Elektronikgeräte-Abfall) 2002/96/EC for reduction of the amount of electronic scrap
from no longer used electrical and electronic devices.
Dispose of professionally.
For disposal, the
iveo Heat
Connect
may be returned to the manufacturer.
Shipping costs are not assumed.
14.
Dimensions
15.
Technical data
Operating voltage
230 V / 50 Hz
Maximum switching output
2000 W
Connections
Stak/Stas3
Radio frequency
868 MHz
Protection type
IP 54
Conformity
CE
Operating temperature range
-30°C to +70°C
Dimensions (approx.)
150 x 35 x 25 mm
Power consumption
< 1 W
Switching time relay
100% ED
Switching contact (max.)
cos φ > 0.8 / 16 A
Weight
120 g