Step 2
Briefly push the PROG button at the transmitter to be programmed.
The additional transmitter is now programmed in the
iveo Heat Connect
.
A connected heating is briefly switched on and off (only for infra-red heatings with visible
light).
8.
Deleting transmitters from the receive
For this process, at least two transmitters must be programmed in the
iveo Heat Connect
Step 1
If a transmitter is already programmed and is NOT to be reprogrammed, push the PROG button
for 3 seconds.
The transmitter indicator lamp flashes once.
A connected heating is briefly switched on and off (only for infra-red heatings with visible
light).
The
iveo Heat Connect
is in learning mode for 1 minute.
Note
:
Learning mode is ended either by a running command (UP or DOWN button) of a
programmed transmitter, or by successful programming.
Step 2
Briefly push the PROG button at the transmitter to be deleted.
The transmitter is now deleted from the iveo Heat.
A connected heating is briefly switched on and off (only for infra-red heatings with visible
light).
9.
New programming when transmitters are defective or lost
Observe that the following mains separation is only performed at the receiver that has no
transmitter available any more.
Note:
If several receivers are switched in parallel, they are switched to service mode at the
same time when the mains is disconnected (step 1). After pushing the PROG button
(step 2) of a new transmitter, all receivers are only programmed to one channel in the
new transmitter.
Step 1
Perform mains disconnection according to the figure
A connected heating is briefly switched on and off 2 x (only for infra-red heatings with visible
light).
Service mode is on
Note:
Service mode can be ended by a running command (UP or DOWN button) of a
programmed transmitter.