English 25
S1.9
LOCKING THE SETTINGS
This setting limits access to parameter groups in
the menu.
0 – no lock
1 – S1
2 – P1, P2, and S1
S1.10
LOCKING THE BUTTONS
This setting locks button function. The operation
of the locking function is described in the section
“Locking the buttons”.
0 – no lock
1 – operation mode,
2 – same as 1 and
functions,
3 – same as 2 and the
desired temp.,
4 – same as 3 and data
browsing and settings.
S1.11
MINIMUM SETTING OF THE DESIRED TEMPERA-
TURE
This setting determines the minimum room tempera
-
ture setting possible.
4–40°C (
6
)
S1.12
MAXIMUM SETTING OF THE DESIRED TEM-
PERATURE
This setting determines the maximum room tem-
perature setting possible.
4–40°C (
30
)
S1.14
ALTITUDE FOR WEATHER FORECAST
This setting enters the altitude of the room unit. This
improves the precision of weather forecasts.
0–1,999m (
300
)
The access to service settings is locked. It is possible to access locked
parameters in the following way: first access the S1 service parameters.
Now press the button and hold it for 10 seconds.
Use the buttons and to move between the C designations of the
controller parameters. Use the button to start the reading of the pa-
rameter values from the controller. By pressing the button again, the
setting value starts flashing.
Change the setting with the buttons and and save it back to the
controller by pressing the button.
The list of parameters can be found in the controller manual.
ACCESS TO CONTROLLER SERVICE SETTINGS