SellEton Scales PS-IN202SS User Manual Download Page 9

PS-IN202SS Indicator 

- 8 -

V2015.05 

Factory 
Reset 
P16 
Normal/Slave 
Mode Setting 

Set the indicator to be normal or slave mode. “n” means normal; “s” 
means slave. Connect the indicator through RS232 with another indicator 
to be used an additional display for “slave mode”. 

N

 

√ 

P17 
Counting 
Mode setting 

Activate / deactivate the counting mode.  “1” is ON, “0” is OFF 

1

√ 

P18 
Animal Mode 

Set the divisions for animal weighing hold function 

XXd 

P19 
Accumulation 
(SS Only) 

Set accumulation modes: Automatic or Manual 
In Automatic mode, it saves weights automatically when it is stable. 

Auto 

Man

√ 

2.7 Communication Menu Descriptions 

This section provides a more detailed description of the selections found in the User Menu 
Chart. Factory-

set defaults are shown in bold with a checkmark (√). 

NAME/CODE 

DESCRIPTION 

CODE/VALUE 

S1 
Baud Rate 

Selects the baud rate for data transmission through the serial port 

1200 
4800 
19200 

2400 

9600√ 

S2 
Data Bits and 
Parity 

Selects the number of data bits and parity of serial transmission. 
"8n" = 8 data bits with no parity bit and one stop bit 
"7O" = 7 data bits with odd parity bit and one stop bit 
"7E" = 7 data bits with even parity bit and one stop bit 
"7n" = 7 data bits with no parity bit and two stop bits 

8n

√ 

7O 
7E 
7n 

S3 
Mode of Serial 
Transmission 

Selects when data will be sent out of the serial port to a printer or 
computer: 
“C” = Continuous Mode; Send Data continuously 
“d” = demand mode; send data when a PRINT command is issued from 
the printer, computer or indicator 

d√ 

S4 
Display Check 

Actuates the function that illuminates all digit segments, decimal points, 
LCD enunciators in a test sequence. Pressing the 

[ZERO]

 key to scroll 

down one level begins the test sequence 

Press [ZERO] key to 
begin sequence 

S5 
Disable the 
lb/kg Key 

Allows the lb/kg to be disabled so that an operator cannot accidentally 
press the key and change the displayed units. 
“0” = Disable the lb/kg key   “1” = Enable the lb/kg key 

1√ 

S6 
Serial Port 
Mode 

Selects the mode of the RS-232 serial port: Refer to Appendix B for 
more information 
“0” = Full Duplex Mode 
“1” = Print Ticket Mode 

1√ 

S7 
ID No. Enable 

Allows the ID number to be disabled in the Print Ticket Mode. Valid only 
when 

S6

 

is set to “1” 

“0” = Disable the ID No.       “1” = Enable the ID No. 

0√ 

S8 
ID No. Entry 

Actuates the function that allows entry of a new ID No. Valid only when 

S6

 

is set to “1”. Pressing the 

[ZERO]

 key to scroll down one level begins 

the sequence. 

0 - 999999

123456√ 

Summary of Contents for PS-IN202SS

Page 1: ...Version 2013 08 PS IN202SS Weight Indicator User s Manual...

Page 2: ...R 2 CONFIGURATION 2 1 SET UP P MENU 2 2 Setup Menu Chart 2 3 Exiting the setup menu 2 4 USER S MENU 2 5 User Menu Chart 2 6 Setup Menu Descriptions 2 7 User Menu Descriptions CHAPTER 3 CALIBRATION 3 1...

Page 3: ...PS IN202SS Indicator 2 V2015 05 Front View of the Indicator FIG1 shows the front view of the indicator FIG 1...

Page 4: ...as shown below in FIG 2 Assemble the cables with the pin assignments shown in FIG 2 FIG 2 1 3 CONNECTION TO A PRINTER OR COMPUTER The indicator contains a standard full duplex RS 232 serial port desi...

Page 5: ...own is the weighing mode c Switch on the indicator The indicator will display P 1 to indicate that it is in Setup P menu mode d Choose the channel you are working on The default channel is 1 You can p...

Page 6: ...Calibration position Up is the calibration mode Down is the weighing mode c Switch on the indicator The display will go through a digit check then go into Normal Operating mode All front panel keys w...

Page 7: ...Chart d To move to the selection level press the ZERO right key once The current saved selection is shown e To view the available selections for the current S heading use the TARE down or PRINT up ke...

Page 8: ...m value varies depending on the local regulations 1d 3d 5d 10d P8 Digital Filter Averages weight readings to produce higher stability The higher the filter setting the greater the stability but the sl...

Page 9: ...op bit 7E 7 data bits with even parity bit and one stop bit 7n 7 data bits with no parity bit and two stop bits 8n 7O 7E 7n S3 Mode of Serial Transmission Selects when data will be sent out of the ser...

Page 10: ...int the header information Valid only when S6 is set to 1 0 Do NOT Print Header 1 Print Header 0 1 S12 Back light set Set back light mode OFF ON and Auto when the display is idle the back light will t...

Page 11: ...nternal A D count and is useful when trying to troubleshoot setup problems b Ensure there are no test weights on the platform and press the ZERO key again to zero out the displayed value c Press the N...

Page 12: ...libration menu b The display will momentarily show CAL 0 followed by a value This value is the zero calibration value and should be recorded in the table below Press any key to continue c The display...

Page 13: ...he displayed value to the span calibration value c After setting the exact value press the NET GROSS key to save the value d If the entered value is greater than zero the display will show E CAL 1 mom...

Page 14: ...isplaying the gross weight T TARE The tare weight has been established in the system lb kg oz PCS lb kg oz PCS Indicates the unit of the displayed weight PCS pieces STABLE This light is illuminated wh...

Page 15: ...the weight shown on the display 4 5 Tare Function To weigh an item in a container the weight of that container must first be subtracted from the overall weight to obtain an accurate weight reading Thi...

Page 16: ...ve until all the weight values are added Press and hold ACCU for 2 seconds to enter the accumulation review mode It will show the first value added Press ACCU once and it will move on to the second va...

Page 17: ...PS IN202SS Indicator 16 V2015 05...

Reviews: