Factory
Reset
P16
Normal/Slave
Mode Setting
Set the indicator to be normal or slave mode. “n” means normal; “s”
means slave. Connect the indicator through RS232 with another indicator
to be used an additional display for “slave mode”.
N
√
S
P17
Counting
Mode setting
Activate / deactivate the counting mode. “1” is ON, “0” is OFF
0
1
√
P18
Animal Mode
Set the divisions for animal weighing hold function
XXd
P19
Accumulation
(SS Only)
Set accumulation modes: Automatic or Manual
In Automatic mode, it saves weights automatically when it is stable.
Auto
Man
√
2.7 Communication Menu Descriptions
This section provides a more detailed description of the selections found in the User Menu
Chart. Factory-
set defaults are shown in bold with a checkmark (√).
NAME/CODE
DESCRIPTION
CODE/VALUE
S1
Baud Rate
Selects the baud rate for data transmission through the serial port
1200
4800
19200
2400
9600√
S2
Data Bits and
Parity
Selects the number of data bits and parity of serial transmission.
"8n" = 8 data bits with no parity bit and one stop bit
"7O" = 7 data bits with odd parity bit and one stop bit
"7E" = 7 data bits with even parity bit and one stop bit
"7n" = 7 data bits with no parity bit and two stop bits
8n
√
7O
7E
7n
S3
Mode of Serial
Transmission
Selects when data will be sent out of the serial port to a printer or
computer:
“C” = Continuous Mode; Send Data continuously
“d” = demand mode; send data when a PRINT command is issued from
the printer, computer or indicator
C
d√
S4
Display Check
Actuates the function that illuminates all digit segments, decimal points,
LCD enunciators in a test sequence. Pressing the
[ZERO]
key to scroll
down one level begins the test sequence
Press [ZERO] key to
begin sequence
S5
Disable the
lb/kg Key
Allows the lb/kg to be disabled so that an operator cannot accidentally
press the key and change the displayed units.
“0” = Disable the lb/kg key “1” = Enable the lb/kg key
0
1√
S6
Serial Port
Mode
Selects the mode of the RS-232 serial port: Refer to Appendix B for
more information
“0” = Full Duplex Mode
“1” = Print Ticket Mode
0
1√
S7
ID No. Enable
Allows the ID number to be disabled in the Print Ticket Mode. Valid only
when
S6
is set to “1”
“0” = Disable the ID No. “1” = Enable the ID No.
0√
1
S8
ID No. Entry
Actuates the function that allows entry of a new ID No. Valid only when
S6
is set to “1”. Pressing the
[ZERO]
key to scroll down one level begins
the sequence.
0 - 999999
123456√