SellEton Scales OP-907 Series User Manual Download Page 17

15

HELPFUL DEFINITIONS

Division: The amount of increments a scale offers. How accurate the scale can be

Capacity: the maximum amount the scale can contain

Initial Zero Range: The percentage of weight allowed on the scale when indicator is powered 

on that will automatically zero. 

example: If initial zero range is set to 10% of the max. capacity and your max. capacity is 

100lbs, you can place up to 10lbs of weight on the scale and when the indicator is powered on, it 

will automatically zero out the weight. 

Manual Zero Range: The percentage of weight allowed on the scale where the indicator will let 

you manually zero (anything above this percent will be tared)

Zero Tracking Range: A subset to the manual zero range; if the weight on the scale 
is not stable, the zero tracking range still allows you to zero within a set division of the 
scale

Zero Tracking Time: A subset to the zero tracking range, it is the time allowed for the 
scale to fall within the zero tracking range tolerance and still qualify to be zero’d

Overload Range: Weight allowance that is out of the set calibrated range. Adds a  
tolerance to the calibrated max. capacity without having to recalibrate. 
example: If your scale has a max. capacity of 1000lbs with a division of 1 and you set 
the overload range to 60, you can add 1060lbs of weight to the scale without it  
displaying an error code

Negative Display: How far you can go in the negative direction before displaying an 
error code

Standstill Time: How fast the scale will stabilize 

Standstill Range: How much the scale can fluctuate before being determined stable

Digital Filter: For filtering moving weight, such as animals, It changes how sensitive 
the scale is to variations in movement. 

Noise Filter: A filter for how susceptible the scale is to general variations

Baud Rate: The rate at which information is transferred in a communication channel. 
example: In the serial port context, “9600 baud” means that the serial port is capable of 
transferring a maximum of 9600 bits per second.

Summary of Contents for OP-907 Series

Page 1: ...www selletonscales com OP 907 SERIES INDICATOR USER S MANUAL OP 907A OP 907B Series...

Page 2: ...et Up 1 Features 2 Specifications 3 Power Supply 4 Displays 5 Display and Key Descriptions 6 Operating Instructions 7 9 Calibration 10 11 Indicator Parameter Settings 12 14 Definitions 15 Connectors 1...

Page 3: ...as it could damage the load cell inside Material that has a static electric charge could influence the weighing Discharge the static electricity of the samples if possible Another solution to the pro...

Page 4: ...l Parameters Accuracy class 3000 e Stimulating voltage 3 3 VDC A D converting speed 10 SPS Load signal range 0 12 8mV Load capacity can connect 4 pcs 350 load cell at most Interval 1 2 5 10 20 50 Disp...

Page 5: ...3 SPECIFICATIONS INDICATOR MEASUREMENTS 5 5 8 10 6 10...

Page 6: ...me use for 10 12 hours to prevent low voltage resulted from self leakage of batter Once charged the battery should last for 45 hours To keep the battery in best condition fully discharge the battery e...

Page 7: ...5 OP 907A LED OP 907B LCD...

Page 8: ...On Off button to enter and exit calibration 2 Hold for 1 second to print The scale is at zero The scale is stable Gross Shows you are in Gross weight mode includes tare default mode Net Shows you are...

Page 9: ...to tare out the weight Unit Selection To switch between measuring units kg lb oz press the UNITS key Tare Function The Tare function is used when you only wish to see the current change in weight not...

Page 10: ...ll flash on the display followed by the total The total will display by flashing between 2 sets of numbers There are 8 digits in total the display will flash 4 at a time the first 4 on the left and th...

Page 11: ...display the average weight sampled from 3 or 5 seconds Set in the C12 Parameter Add animal to scale and press HOLD Indicator screen will show LOC for 3 or 5 seconds then display the average weight fr...

Page 12: ...n appears The C3 channel adjusts the divisions on the scale A value of 1 selected and C2 set to 1 the scale will read in 0 1 lb increments 13 Press SET to set the value The display will now show C04 1...

Page 13: ...he scale will count down from 10 to 0 Once 0 has been reached the display will show CALEnd 27 Press SET to continue The display will now show C07 28 Press ON OFF to save and exit the setup menu 29 The...

Page 14: ...labeled under each indicator button 3 Press the SET key to enter edit the parameter setting 4 Press the ON OFF key to save and exit settings at any time Table 1 Calibration Parameter Settings Function...

Page 15: ...ght 3 Auto hold Automatically holds data when stable 4 Average hold for animal weighing averages the weight from a sample of 3 or 5 seconds Set in parameter C12 Hold Time C12 If you chose C11 4 this s...

Page 16: ...1 second 2 2 seconds 3 3 seconds Overload Range C24 00 turn off overload range 01 99d overload range setting d division Negative Display C25 0 9d 10 10 max capacity 20 20 max capacity 50 50 max capac...

Page 17: ...the time allowed for the scale to fall within the zero tracking range tolerance and still qualify to be zero d Overload Range Weight allowance that is out of the set calibrated range Adds a tolerance...

Page 18: ...wire load cell connections are both okay Please contact us directly if you have other special needs for your application Quick Disconnect as shown below QUICK DISCONNECT CONNECTION DIAGRAM DB9 SERIAL...

Page 19: ...t Communication Format is done using ASCII as shown below CR LF S 1 S 2 S 3 Data S 4 S1 weight status ST standstill US not standstill OL overload S2 weight mode GS gross mode NT net mode S3 weight of...

Page 20: ...e the max capacity Use correct weight within the defined range ERR2 During calibration the weight is below the minimum required weight The calibration weight minimum is 10 of the max capacity set in C...

Reviews: