SELET CBM13 Reference Manual Download Page 9

STRUMENTAZIONE A MICROCONTROLLORE - 

MICROCONTROLLER INSTRUMENTS 

 9 

ALLO SPEGNIMENTO IL TIMER EFFETTUA 
UNA MEMORIZZAZIONE DEL CONTEGGIO IN 
EEPROM E IN ACCENSIONE, SALVO 
INGRESSO RST ATTIVO, RIPRESENTA LO 
STESSO DATO SUL VISUALIZZATORE  
 

b = 0

   

DURING SWITCH-OFF TIME ALL DATA 
ARE SAVED IN EEPROM AND DURING 
SWITCH-ON TIME THIS VALUE IS SHOWN 
ON DISPLAY AS ACTUAL  IF RST INPUT IS 
ON.  

ALLO SPEGNIMENTO IL TIMER NON 
MEMORIZZA L'ULTIMO DATO E RIPROPONE 
SUL VISUALIZZATORE IL DATO DI 
PARTENZA, CIOE' 00000 SE CONTANTE 
OPPURE IL VALORE DI SET (SET2) SE 
DECONTANTE  

b = 1

  

DURING SWITCH-OFF TIME THE LAST 
VALUE IS NOT SAVED. IN SWITCH-ON 
TIME DISPLAY INDICATES 00000 IF 
COUNTING UP, OR SET (SET2) VALUE IF 
COUNTING DOWN. 

 

a : 

TRAMITE IL PARAMETRO 

a

 E' POSSIBILE INTRODURRE UN FILTRO DIGITALE PER LA LIMITAZIONE 

DELLA FREQUENZA DI INGRESSO. 

a : 

AN INPUT FILTER, JUST TO CHOOSE THE INPUT FREQUENCY, SHOULD BE SET BY 

PARAMETER. 

 

FREQUENZA MASSIMA 5 KHz  

a = 0  

MAXIMUM FREQUENCY  5 KHz 

FREQUENZA MASSIMA  100 Hz  

a = 1  

MAXIMUM FREQUENCY  100 Hz 

FREQUENZA MASSIMA   10  Hz  

a = 2  

MAXIMUM FREQUENCY    10 Hz 

FREQUENZA MASSIMA      1 Hz  

a = 3  

MAXIMUM FREQUENCY     1 Hz 

 
u : 

CON IL PARAMETRO 

u

, SI IMPOSTA IL CONTEGGIO 

CONTANTE ( 0 ) 

O

 DECONTANTE (1)

. CONTANTE 

SIGNIFICA CHE AD UN RESET IL CONTATORE SI PREDISPONE A ZERO O AD UN VALORE DI OFFSET, ED 
INCREMENTA SINO AL RAGGIUNGIMENTO DEL SET, OVVIAMENTE SE QUESTO E' POSITIVO. 
DECONTANTE SIGNIFICA CHE AD UN RESET IL CONTATORE SI PREDISPONE AL SET2 SENZA ATTIVARE 
L'USCITA, MENTRE QUESTA SI ATTIVA A ZERO. 

IMPORTANTE

 : NEL CAMBIARE IL PARAMETRO 

u

 SI ANNULLANO LE IMPOSTAZIONI DEI SET E 

DELL'OFFSET, PER CUI OCCORRE RIPRISTINARLI. 
 

u : 

BY 

u

 PARAMETER AN 

INCREMENTAL (0)

 OR A 

DECREMENTAL (1

) COUNT SHOULD BE CHOICE. 

INCREMENTAL COUNT MEANS RESET  -TO-ZERO OR RESET-TO-OFFSET AND COUNTING UP TO SET, IF 
THIS IS POSITIVE. 
DECREMENTAL COUNT MEANS RESET-TO-SET2 WITHOUT OUTPUT ACTIVATION AND COUNTING UP TO 
ZERO OR UP TO OFFSET WITH OUTPUT ACTIVATION. 

IMPORTANT

 THE 

u

 PARAMETER CHANGE MEANS A RESET OF SETS AND OFFSET VALUES, SO THEY 

HAVE TO BE PROGRAMMED AGAIN 

 

PASS : 

SELEZIONA LA PAROLA CHIAVE PER ACCEDERE ALLA PROGRAMMAZIONE, CAMPO 1  - 999999 

(99999) ( SE 0 L'ACCESSO ALLE PROGRAMMAZIONI E' DIRETTO ), PROTETTO DA PASSWORD AZIENDALE  

371372  (71372). 

ASSUME PROTEZIONE IN UN CAMPO DA 1 A 99999 PER IL CBM1 MENTRE 999999 PER LA 

SERIE CBM5 E CBM6. IN OGNI CASO IL NUMERO 

71372

 PER IL CBM1 E 

371372

 PER IL CBM5 E CBM6 E' IL 

NUMERO DI SBLOCCO FISSATO DALLA CASA COSTRUTTRICE DI TUTTI I MODELLI A 
MICROPROCESSORE. 
E' POSSIBILE INOLTRE IMPOSTARE UN LIVELLO DI PASSWORD CHE DETERMINA QUALE VOCE 
PROGRAMMABILE DALL'UTENTE DEVE NECESSARIAMENTE RESTARE FUORI DALLA PASSWORD. 
RIMANE ESCLUSA LA SERIE CBM60 NON AVENDO SET (VEDI TABELLA DEI LIVELLI).

 

PASS : 

SELECT THE PASSWORD TO ENTER IN SETUP, RANGE 0 - 99999 (99999)( IF 0 ENTRY IS DIRECT ), 

PROTECTED BY FIRM PASSWORD  371372

 (71372). 

SUCH A PASSWORD IS VOID IF NOT PROGRAMMED 

(THAT IS IF THE VALUES ARE LEFT AT 0 ). PROTECTION IS GIVEN ON A RANGE OF 1 TO 99999 FOR CBM1 
SERIES WHILE 999999 FOR CBM5 AND CBM6 . 
IN ANY EVENT THE NUMBER 

71372

 IS THE  PASSWORD OF CBM1 WHILE 

371372

 IS THE PASSWORD OF 

CBM5 AND CBM6 SERIES. THIESE NUMBERS ARE  FIXED BY THE MANUFACTURER ON ALL 
MICROPROCESSING MODELS. 

 

L.PASS : 

SELEZIONA, SECONDO UNA TABELLA, QUALI DATI RENDERE DISPONIBILI FUORI DALLA 

PASSWORD 

L.PASS : 

SELECT, FOLLOWING A TABLE, THE TYPE OF DATA WITH FREE ACCESS 

 

 

 

 L.PASS 0  

 L.PASS 1  

L.PASS 2  

CBM  

ACCESSO SET 

 

SET ACCESS

  

/  

2  

1-2  

 

 

Summary of Contents for CBM13

Page 1: ...MANUALE DI RIFERIMENTO CBM13 CBM53 CBM60 CBM63 REFERENCE MANUAL 2000 REV 3 1 Selet Sensor srl I 10151 Torino Via Pozzo 16 Tel 0039 011 4537811 Fax 0039 011 4537868 e mail info selet it ...

Page 2: ... con il dispositivo non alimentato make electrical connections with no power on the instrument Prestare attenzione alla correttezza del collegamento elettrico Attention on the electrical connections Non collegare i morsetti liberi o privi di indicazione not connect free or no signed plug in QUALUNQUE ERRORE ANNULLA LA GARANZIA EVERY MISTAKE NULLIFY WARRANTY Utilizzare preferibilmente cavo schermat...

Page 3: ...ODIFICHE CHE RITENGA OPPORTUNE SENZA PREAVVISO MANUFACTURER RESERVE ITSELF THE RIGHT TO MAKE ALL THE SUITABLE CHANGE WITHOUT NOTICE 4 IL PERIODO DI GARANZIA E DI UN ANNO DALLA DATA DI VENDITA WARRANTY TIME IS ONE YEAR AFTER SOLD 5 VIENE RICONOSCIUTA LA GARANZIA SOLO NEL CASO CHE L ARTICOLO NON SIA STATO A APERTO MODIFICATO MANOMESSO B COLLEGATO CORRETTAMENTE IN QUESTO CASO E OBBLIGATORIO FORNIRE S...

Page 4: ...IONE DEL SET1 USCITA NA1 CHIUSA MEANS SET1 ON OUTPUT NA1 CLOSED SEGMENT O SPENTO INDICA CHE LA VISUALIZZAZIONE E NEL CAMPO POSITIVO MEANS THE INDICATION IS IN POSITIVE RANGE SEGMENT O ACCESO INDICA CHE LA VISUALIZZAZIONE E NEL CAMPO NEGATIVO MEANS THE INDICATION IS IN NEGATIVE RANGE L2 SET 2 INDICA L ATTIVAZIONE DEL SET2 USCITA NA2 CHIUSA MEANS SET2 ON OUTPUT NA2 CLOSED CARATTERISTICHE GENERALI GE...

Page 5: ...GND GND INGRESSO DI CONTEGGIO 1 COUNT INPUT 1 IN1 IN1 IN1 INGRESSO DI CONTEGGIO 2 COUNT INPUT 2 IN2 IN2 IN2 SELEZIONE NPN PNP NPN PNP SELECT N P N P INGRESSO BLOCCO CONTEGGIO GATE INPUT EN EN EN INGRESSO AUSILIARIO AUX INPUT IN3 IN3 INGRESSO DI RESET O CARICO OFFSET RESET INPUT OR OFFSET LOADING RST RST RST USCITA SINGOLO SET SINGLE SET OUPUT NA1 NC C NA2 NA1 C1 NC1 NA2 C2 NC2 NA1 NC C NA2 USCITA ...

Page 6: ...NUMERO DI IMPULSI GIRO O LINEARI DEL TRASDUTTORE FATTORE DI DIVISIONE CAMPO 1 A 999999 99999 n NUMBER OF PULSES FOR REVOLUTION OR LINEAR PULSE OF TRANSDUCER DIVISION FACTOR RANGE 1 TO 999999 99999 S SVILUPPO O RISOLUZIONE DETERMINATI DAGLI IMPULSI DEL TRASDUTTORE FATTORE DI MOLTIPLICAZIONE CAMPO 1 A 999999 99999 S DEVELOPMENT OR RISOLUTION GIIVEN BY NR OF PULSES OF TRANSDUCER MULTIPLY FACTOR RANGE...

Page 7: ...T SIGNIFICA CHE AZZERANDO IL CONTEGGIO IL CONTATORE VA AL VALORE DI OFFSET O ZERO RELATIVO LEGEND THIS TABLE SHOWS RESET MODALITY PANEL RESET INPUT RST IS ALWAYS ENABLED WHILE FRONT RESET SHOULD BE ENABLED OR NOT DISPLAY 0 MEANS WHEN A RESET SIGNAL OCCURS COUNTER IS RESET TO ZERO DISPLAY OFFSET MEANS WHEN A RESET SIGNAL OCCURS COUNTER IS RESET TO OFFSET OR RELATIVE ZERO A SELEZIONA L INTERVENTO DE...

Page 8: ...NT TO COUNT IN BOTH WAYS DURING THE ON TIME OF OUTPUTS THE DISPLAY INDICATES SET OR SET2 VALUE CICLO AUTOMATICO CON RESET DIPENDENTE DAL SET2 AZZERAMENTO IMMEDIATO DEL CONTATORE L USCITA PERMANE ATTIVA PER LA DURATA DEL TEMPO t L USCITA RELATIVA AL SET1 E ATTIVA PER VALORI UGUALI O MAGGIORI E SI DISATTIVA SU VALORI MINORI IN SINGOLO SET ASSUME LO STESSO FUNZIONAMENTO DEL PARAMETRO 2 c 4 AUTOMATIC ...

Page 9: ...RIPRISTINARLI u BY u PARAMETER AN INCREMENTAL 0 OR A DECREMENTAL 1 COUNT SHOULD BE CHOICE INCREMENTAL COUNT MEANS RESET TO ZERO OR RESET TO OFFSET AND COUNTING UP TO SET IF THIS IS POSITIVE DECREMENTAL COUNT MEANS RESET TO SET2 WITHOUT OUTPUT ACTIVATION AND COUNTING UP TO ZERO OR UP TO OFFSET WITH OUTPUT ACTIVATION IMPORTANT THE u PARAMETER CHANGE MEANS A RESET OF SETS AND OFFSET VALUES SO THEY HA...

Page 10: ...D SHIFT LEFT THE JUMPER EXECUTE THIS OPERATION WITHOUT SUPPLY TO THE COUNTER PNP NPN AVVERTENZA NON CORTOCIRCUITARE TUTTI I TRE PIN INSIEME PER LA SERIE 72X72 E 48X96 CONNETTERE IL MORSETTO N P A 12 PER INGRESSI NPN OPPURE N P CON GND PER INGRESSI PNP WARNING DO NOT SHORT CIRCUIT ALL THREE PINS TOGETHER CONNECTED N P WITH 12 FOR NPN INPUT OR N P WITH GND FOR PNP INPUT ON 72x72 AND 48x96 TYPE VISTA...

Page 11: ...IONALI IL PARAMETRO INP SIA PROGRAMMATO ADEGUATAMENTE 1 0 NON RESETTA NON BLOCCA IL CONTEGGIO 1 1 VERIFICARE CHE LA LOGICA USATA SIA COMPATIBILE CON IL SEGNALE DI INGRESSO E O CHE IL MORSETTO N P SIA COLLEGATO 1 2 VERIFICARE CHE IL SEGNALE ARRIVI IN MORSETTIERA 2 0 NON VISUALIZZA CORRETTAMENTE 2 1 VERIFICARE I RAPPORTI DI MOLTIPLICAZIONE E DIVISIONE 2 2 VERIFICARE CHE LA VELOCITA O FREQUENZA DI CO...

Page 12: ... D IN G R E S S I P E R E N C O D E R IN P U T S F O R E N C O D E R R E L A Y S IN G R E S S I P E R S E N S O R I P N P 1 2 IN 1 IN 2 M IC R O M IC R O G N D IN 1 IN 2 N A M U R N A M U R G N D IN 1 IN 2 M IC R O M IC R O IN G R E S S I P E R S E N S O R I N P N U S C IT A N P N O U T 1 O U T 2 C O M N P N O U T P U T U S C IT A P N P P N P O U T P U T O U T 1 O U T 2 C O M 1 2 N P 7 2 X 7 2 4 8...

Reviews: