SELET CBM13 Reference Manual Download Page 7

STRUMENTAZIONE A MICROCONTROLLORE - 

MICROCONTROLLER INSTRUMENTS 

 7 

IN2

  CLOCK INCREMENTALE SUL FRONTE DI 

SALITA  

 

IN2

 UP COUNTING ON RISE TIME  

IN1

 CLOCK INCREMENTALE SUL FRONTE DI 

DISCESA  

InP = 8 

 

IN1

 UP COUNTING ON FALL TIME 

IN2

  CLOCKINCREMENTALE SUL FRONTE DI 

DISCESA 

 

IN2

 UP COUNTING ON FALL TIME  

  

d : 

PROGRAMMAZIONE VIRGOLA 

: DECIMAL POINT PROGRAM 

d

 

 

 RAFFIGURAZIONE CBM 1          

 

INDICATION  

 

 RAFFIGURAZIONE  CBM5 – CBM6 

 

INDICATION  

0  

99999 

999999  

1  

9999.9 

99999.9  

2  

999.99 

9999.99  

  

99.999 

999.999  

4  

 

9.9999 

 

99.9999  

 

9

 .

99999 

 
r : 

ABILITAZIONE DEL RESET DA TASTIERA, CAMPO 0 - 5

 

r : 

FRONT RESET  KEY ENABLE, RANGE 0 – 5 

 

 

 MORSETTIERA 

 TERMINALS  

 

TASTIERA 

KEYBOARD 

     

DISPLAY = 0  

DISABILITATO 

DISABLED 

 

1  

DISPLAY = OFFSET 

DISABILITATO 

DISABLED 

 

2  

DISPLAY = 0  

DISPLAY = 0 

3  

DISPLAY = OFFSET  

DISPLAY = 0 

4  

DISPLAY = 0  

DISPLAY = OFFSET 

5  

DISPLAY = OFFSET  

DISPLAY = OFFSET 

 
LEGENDA: 
QUESTA TABELLA DEFINISCE LE MODALITA' DI RESET. IL RESET DELLA MORSETTIERA ( INGRESSO 

RST

 

) E' SEMPRE ABILITATO MENTRE QUELLO PRESENTE SUL PANNELLO FRONTALE SI PUO' ABILITARE O 
DISABILITARE. 
QUANDO TROVIAMO 

DISPLAY = 0

 SIGNIFICA CHE AZZERANDO IL CONTEGGIO, IL CONTATORE VA A 

ZERO. 
QUANDO TROVIAMO 

DISPLAY = OFFSET

 SIGNIFICA CHE AZZERANDO IL CONTEGGIO, IL CONTATORE VA 

AL VALORE DI OFFSET O ZERO RELATIVO. 

LEGEND 
THIS TABLE SHOWS RESET MODALITY. PANEL RESET INPUT (

RST

) IS ALWAYS ENABLED, WHILE FRONT 

RESET SHOULD BE ENABLED OR NOT. 

DISPLAY = 0 

MEANS WHEN A RESET SIGNAL OCCURS, COUNTER IS RESET TO ZERO. 

DISPLAY = OFFSET

 MEANS WHEN A RESET SIGNAL OCCURS, COUNTER IS RESET TO OFFSET OR 

RELATIVE ZERO. 

 

A : 

SELEZIONA L'INTERVENTO DEL RESET DA TASTIERA, 

 

A : 

SELECT THE FRONT RESET ACTION, IMMEDIATE OR DELAYED (3sec). 

 
                      0 =  ISTANTANEO                           

  

IMMEDIATE 

                      

1 = RITARDATO DI TRE SECONDI 

                        DELAYED (3sec) 

 
t : 

PROGRAMMAZIONE DEL TEMPO DI MANTENIMENTO DELLE USCITE, CAMPO 0,1  - 99,9 SECONDI, 

VALIDO SE IL CICLO DEI RELE' E' IMPULSIVO, PER LE USCITE SET1 E SET2. TIMER INTERNO, E' ATTIVO 
SE IL CICLO PROGRAMMATO NON E' UGUALE A ZERO. IL CAMPO DI REGOLAZIONE E' DA 0,1 SECONDI A 
99,9 SECONDI CON LA PRECISIONE DI 25 mSec.  

t : 

OUTPUTS SWITCH-ON TIME, RANGE 0.1 - 99.9 SECONDS, RIGHT ONLY IF RELAY CYCLE IS IMPULSIVE, 

FOR SET1 AND SET2 OUTPUTS. INTERNAL TIIMER AVAILABLE ONLY IF THE PROGRAMMED CYCLE IS 
NOT EQUAL TO ZERO. THE ADJUSTEMENT RANGE IS FROM 0.1 SECONDS TO 99.9 SECONDS WITH 25 
mSec OF ACCURACY. 

 

c : 

SELEZIONA IL TIPO DI CICLO. E' LEGATA AL PARAMETRO 

F

 CHE VINCOLA IL FUNZIONAMENTO COME 

SINGOLA O DOPPIA USCITA. 

c : 

SELECT THE TYPE OF CYCLE. IT FOLLOWS 

F

 PARAMETER THAT CHOOSE THE TWO OR ONE OUTPUT 

WORKING. 
 

Summary of Contents for CBM13

Page 1: ...MANUALE DI RIFERIMENTO CBM13 CBM53 CBM60 CBM63 REFERENCE MANUAL 2000 REV 3 1 Selet Sensor srl I 10151 Torino Via Pozzo 16 Tel 0039 011 4537811 Fax 0039 011 4537868 e mail info selet it ...

Page 2: ... con il dispositivo non alimentato make electrical connections with no power on the instrument Prestare attenzione alla correttezza del collegamento elettrico Attention on the electrical connections Non collegare i morsetti liberi o privi di indicazione not connect free or no signed plug in QUALUNQUE ERRORE ANNULLA LA GARANZIA EVERY MISTAKE NULLIFY WARRANTY Utilizzare preferibilmente cavo schermat...

Page 3: ...ODIFICHE CHE RITENGA OPPORTUNE SENZA PREAVVISO MANUFACTURER RESERVE ITSELF THE RIGHT TO MAKE ALL THE SUITABLE CHANGE WITHOUT NOTICE 4 IL PERIODO DI GARANZIA E DI UN ANNO DALLA DATA DI VENDITA WARRANTY TIME IS ONE YEAR AFTER SOLD 5 VIENE RICONOSCIUTA LA GARANZIA SOLO NEL CASO CHE L ARTICOLO NON SIA STATO A APERTO MODIFICATO MANOMESSO B COLLEGATO CORRETTAMENTE IN QUESTO CASO E OBBLIGATORIO FORNIRE S...

Page 4: ...IONE DEL SET1 USCITA NA1 CHIUSA MEANS SET1 ON OUTPUT NA1 CLOSED SEGMENT O SPENTO INDICA CHE LA VISUALIZZAZIONE E NEL CAMPO POSITIVO MEANS THE INDICATION IS IN POSITIVE RANGE SEGMENT O ACCESO INDICA CHE LA VISUALIZZAZIONE E NEL CAMPO NEGATIVO MEANS THE INDICATION IS IN NEGATIVE RANGE L2 SET 2 INDICA L ATTIVAZIONE DEL SET2 USCITA NA2 CHIUSA MEANS SET2 ON OUTPUT NA2 CLOSED CARATTERISTICHE GENERALI GE...

Page 5: ...GND GND INGRESSO DI CONTEGGIO 1 COUNT INPUT 1 IN1 IN1 IN1 INGRESSO DI CONTEGGIO 2 COUNT INPUT 2 IN2 IN2 IN2 SELEZIONE NPN PNP NPN PNP SELECT N P N P INGRESSO BLOCCO CONTEGGIO GATE INPUT EN EN EN INGRESSO AUSILIARIO AUX INPUT IN3 IN3 INGRESSO DI RESET O CARICO OFFSET RESET INPUT OR OFFSET LOADING RST RST RST USCITA SINGOLO SET SINGLE SET OUPUT NA1 NC C NA2 NA1 C1 NC1 NA2 C2 NC2 NA1 NC C NA2 USCITA ...

Page 6: ...NUMERO DI IMPULSI GIRO O LINEARI DEL TRASDUTTORE FATTORE DI DIVISIONE CAMPO 1 A 999999 99999 n NUMBER OF PULSES FOR REVOLUTION OR LINEAR PULSE OF TRANSDUCER DIVISION FACTOR RANGE 1 TO 999999 99999 S SVILUPPO O RISOLUZIONE DETERMINATI DAGLI IMPULSI DEL TRASDUTTORE FATTORE DI MOLTIPLICAZIONE CAMPO 1 A 999999 99999 S DEVELOPMENT OR RISOLUTION GIIVEN BY NR OF PULSES OF TRANSDUCER MULTIPLY FACTOR RANGE...

Page 7: ...T SIGNIFICA CHE AZZERANDO IL CONTEGGIO IL CONTATORE VA AL VALORE DI OFFSET O ZERO RELATIVO LEGEND THIS TABLE SHOWS RESET MODALITY PANEL RESET INPUT RST IS ALWAYS ENABLED WHILE FRONT RESET SHOULD BE ENABLED OR NOT DISPLAY 0 MEANS WHEN A RESET SIGNAL OCCURS COUNTER IS RESET TO ZERO DISPLAY OFFSET MEANS WHEN A RESET SIGNAL OCCURS COUNTER IS RESET TO OFFSET OR RELATIVE ZERO A SELEZIONA L INTERVENTO DE...

Page 8: ...NT TO COUNT IN BOTH WAYS DURING THE ON TIME OF OUTPUTS THE DISPLAY INDICATES SET OR SET2 VALUE CICLO AUTOMATICO CON RESET DIPENDENTE DAL SET2 AZZERAMENTO IMMEDIATO DEL CONTATORE L USCITA PERMANE ATTIVA PER LA DURATA DEL TEMPO t L USCITA RELATIVA AL SET1 E ATTIVA PER VALORI UGUALI O MAGGIORI E SI DISATTIVA SU VALORI MINORI IN SINGOLO SET ASSUME LO STESSO FUNZIONAMENTO DEL PARAMETRO 2 c 4 AUTOMATIC ...

Page 9: ...RIPRISTINARLI u BY u PARAMETER AN INCREMENTAL 0 OR A DECREMENTAL 1 COUNT SHOULD BE CHOICE INCREMENTAL COUNT MEANS RESET TO ZERO OR RESET TO OFFSET AND COUNTING UP TO SET IF THIS IS POSITIVE DECREMENTAL COUNT MEANS RESET TO SET2 WITHOUT OUTPUT ACTIVATION AND COUNTING UP TO ZERO OR UP TO OFFSET WITH OUTPUT ACTIVATION IMPORTANT THE u PARAMETER CHANGE MEANS A RESET OF SETS AND OFFSET VALUES SO THEY HA...

Page 10: ...D SHIFT LEFT THE JUMPER EXECUTE THIS OPERATION WITHOUT SUPPLY TO THE COUNTER PNP NPN AVVERTENZA NON CORTOCIRCUITARE TUTTI I TRE PIN INSIEME PER LA SERIE 72X72 E 48X96 CONNETTERE IL MORSETTO N P A 12 PER INGRESSI NPN OPPURE N P CON GND PER INGRESSI PNP WARNING DO NOT SHORT CIRCUIT ALL THREE PINS TOGETHER CONNECTED N P WITH 12 FOR NPN INPUT OR N P WITH GND FOR PNP INPUT ON 72x72 AND 48x96 TYPE VISTA...

Page 11: ...IONALI IL PARAMETRO INP SIA PROGRAMMATO ADEGUATAMENTE 1 0 NON RESETTA NON BLOCCA IL CONTEGGIO 1 1 VERIFICARE CHE LA LOGICA USATA SIA COMPATIBILE CON IL SEGNALE DI INGRESSO E O CHE IL MORSETTO N P SIA COLLEGATO 1 2 VERIFICARE CHE IL SEGNALE ARRIVI IN MORSETTIERA 2 0 NON VISUALIZZA CORRETTAMENTE 2 1 VERIFICARE I RAPPORTI DI MOLTIPLICAZIONE E DIVISIONE 2 2 VERIFICARE CHE LA VELOCITA O FREQUENZA DI CO...

Page 12: ... D IN G R E S S I P E R E N C O D E R IN P U T S F O R E N C O D E R R E L A Y S IN G R E S S I P E R S E N S O R I P N P 1 2 IN 1 IN 2 M IC R O M IC R O G N D IN 1 IN 2 N A M U R N A M U R G N D IN 1 IN 2 M IC R O M IC R O IN G R E S S I P E R S E N S O R I N P N U S C IT A N P N O U T 1 O U T 2 C O M N P N O U T P U T U S C IT A P N P P N P O U T P U T O U T 1 O U T 2 C O M 1 2 N P 7 2 X 7 2 4 8...

Reviews: