Selesta Ingegneria S.p.A. 

 

RFIDat

 is equipped with a long life and rechargeable Metalhydrated Nickel 

batteries, an LCD display and a key with LED indicator. 
 

 

 
 

 
 
 
 

 

 
 

 

 

 

RFIDock/x: docking station units 

 

RFIDock/M/S and RFIDock/L are the docking station units used to transfer data 
recorded in the 

RFIDat 

memory to a PC equipped with a specific software product. 

 

Instruction Manual – Ver. 1.4 

 16/10/2009 – pag. 4 of 12 

Selesta Ingegneria S.p.A. 

 

The indicator placed on the 

RFIDat

 display shows with good approximation 

the battery level.   
 

Attention

:  the 

RFIDat

’s are shipped with the internal battery partially 

charged (about 30%) to preserve its conditions.   
  

Attention

:  it is 

MANDATORY

 to charge the 

RFIDat

  batteries for at least 

30 hours before its first use or its storage 
   

 

Attention

: every 5 months it is necessary to completely recharge (at least 

30 hours) the 

RFIDat

 battery also in case it has been stored. This operation 

allows to maintain the battery in good state of efficiency. This time can be 
reduced in case of storage at high temperature. 
 

 

Attention

: in case of  non complete recharging cycle (for instance if only 

1 hour), a NOT reliable value for the battery level could be visualized on 
the 

RFIDat

 display. 

Maintenance and Safety 

 

The 

RFIDat

, under correct conditions of use, doesn't require any maintenance 

operation. Nevertheless, periodic cleaning operations are recommended. 
These must be done using a soft and not abrasive cloth, slightly dampened 
with water.  

 

Attention

: the improper use of the system components or not 

respecting the instructions reported in this manual, can involve 
damages to people, animals and/or goods. The producer declines any 
responsibility. 

  

 

Attention

: the use of the products could have restrictions imposed by 

the norms of the Country where they are used. The user is therefore 
bound to verify the possible restrictions and to respect the current 
national norms.    

 

 

Instruction Manual – Ver. 1.4 

 16/10/2009 – pag. 9 of 12 

RFIDock/M 

 

RFIDock/S

   

Modular docking station unit with: 

 

  temporary memory with 8.000 readings capacity 

and function for: 

  

communication management between 

RFIDat

 and 

PC 

 

 

RFIDat

 batteries recharging 

Types of connection to PC 

  Serial (EIA RS232C)   

  USB    

  Ethernet 

LED  indicators 

  Power on 

  Data transmission in progress 

  

RFIDat 

reader inside docking unit 

RFIDat

 readers battery 

charging and recharging 

With induction technology 

Power source 

12VDC, 700mA from RFIDock/AL 

Available  configurations 

1, 2, 4, 8 docking  units  (up to 7

 RFIDock/s

Installation 

On desk or wall 

Dimensions and weight  

Single module: 55 x 48 x 83 mm, 74 g 

PC connections

 

   

USB/AL

  

  USB adapter, powered from USB 

  

Ethernet/232

  

  RS232C / Ethernet  converter 

  

USB/232  

  RS232/USB cable converter 

Assigned name 

Time and Date  

Master Mode indicator and reading 

counter from RFID transponder 

Battery level indicator 

Key and LED indicator 

Reading counter from other 

RFIDat when in Master Mode  

Summary of Contents for RFIDat

Page 1: ...device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation NOTE This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential i...

Page 2: ...1 4 16 10 2009 pag 2 of 12 Selesta Ingegneria S p A Technical assistance To get further information and assistance please contact the authorized local Reseller Equipment and battery disposal End of life treatment of electric and electronic equipment applicable in all the Countries of the European Union and in other European Countries with diversified collection systems The products comply with the...

Page 3: ...y derive to people goods or animals as a consequence of not observing the prescribed indications is declined Instruction Manual Ver 1 4 16 10 2009 pag 10 of 12 Selesta Ingegneria S p A Components technical characteristics RFIDat hand held terminal RFIDat reads in Radio Frequency mode the internal ID code of passive trasponders TAGs and at each reading records in its memory date time TAG ID code an...

Page 4: ...eaning operations are recommended These must be done using a soft and not abrasive cloth slightly dampened with water Attention the improper use of the system components or not respecting the instructions reported in this manual can involve damages to people animals and or goods The producer declines any responsibility Attention the use of the products could have restrictions imposed by the norms ...

Page 5: ...d in single reading mode the duration of its battery is more then 60 days if it s used in continuous reading mode its battery allows about 3 000 readings The battery life depends on environmental factors such as temperature humidity ecc To charge the battery it s neccesary to lodge the RFIDat in the powered RFIDock M S or RFIDock L units Instruction Manual Ver 1 4 16 10 2009 pag 8 of 12 Selesta In...

Page 6: ... of the LED indicator During the flashing the reader waits for the TAG reading about 10 seconds 2 Move the RFIDat close to the TAG as shown in the figure 3 The TAG reading completion is confirmed by a short beep with the blue LED on for three seconds Consequently the number of readings performed shown on the display is increased by 1 4 at the end of the reading operation RFIDat automatically retur...