7
M965652 Rev. 1.5 (1/16)
Unit #2
Unit #3
Fig. 3
10 ft.
EXTENSION
CABLE
AC POWER
SUPPLY
AC HARDWIRE
POWER SUPPLY
*MAXIMUM OF 15 UNITS PER
AC POWER SUPPLY.
10' MAXIMUM CABLE
LENGTH BETWEEN UNITS.
OR
Unit #1
Already installed
C
MULTI-AC VERSION (DAISY-CHAIN); Fig. 3, 3a
Important: All control box covers must be removed before beginning to make daisy-chain connections.
Disconnect the first unit’s Y-Adapter from power supply before making daisy-chain connections.
Note: For Unit #1 electrical instructions, refer to section B (page 5).
For subsequent Units, refer to instructions below...
1.RemoveCOVERSfromallCONTROLBOX (3).
2.Insertperviousunit’s10’EXTENSION(11a) through
grayGROMMET
(5b) and connect to single terminal of
Y-ADAPTER
(11).
3.Removesolidblackpluggrommetfromleftsideofall
CONTROLBOX
(3), and replace with GRAY
GROMMET
(5b). (Supplied with each Faucet).
4.Feed27"EXTENSIONCABLES (2) through the top of
CONTROLBOX
(3).Connectone27
"
EXTENSION
CABLE
(2)totheSOLENOIDCABLE (7), and the other
to either of the two available terminals of the
Y-ADAPTER
(11). Connect the current unit’s 10
'
EXTENSION
(10a) to available terminal of the
Y-ADAPTER
(11).
5.Feedtheotherendofthe10ft.EXTENSION(10b)
throughthetwoGRAYGROMMETS
(6a and 6b) and
connect to the single terminal of the next unit’s
Y-ADAPTER
(11).PlaceY-ADAPTER(11) into
CONTROLBOXT
(3).
6. Repeat Steps above for each additional Unit, for a
Max.of15UnitsononeACPOWERSUPPLY.
7. Reinstall CONTROLBOXCOVERS.Tightencover
screws firmly.
CAUTION: Use only American Standard supplied cable sets. Using non-AS supplied cables, or cutting, splicing or
modifying any components will void the warranty.
Unit #2 Detail
Fig. 3a
5
5b
10b
6a
6b
10a
7
2
2
11
11a
3