SE10 Manual
12
Selectronic Australia
Indicator
Setting
LED (1) ON
LED (2) ON
LED (3) ON
LED (4) ON
ALL LEDs ON
16 watts
12 watts
8 watts
4 watts
Inverter will remain ON at all times. This could
be used if a fax machine or VCR is required to
stay on at all times. Be aware that this will use
more power from your battery.
Low Volts Adjust LED (6) (red) ON
To avoid total discharging of your battery the SE10 shuts down at a pre-set
low voltage. As all batteries are different, so too is the minimum voltage they
should be discharged to. The SE10 will leave the factory with a setting of
22.0 volts
, change this setting if required.
Hold the Mode button (7) down until LED (6) comes ON, (approximately 2
seconds) indicating you are ready to adjust this setting. Now press the Mode
button (7) until the desired value is sought. LEDs (1) – (4) will return to
either Status or Voltmeter after 20 seconds.
Indicator
Setting
LED (1) ON
LED (2) ON
LED (3) ON
LED (4) ON
23.0 volts
22.0 volts
21.0 volts
20.0 volts