Proximity Access wiring detail for Landing/Deck Access if required.
Digital Audio
Installation Manual
SelectLine Controller
PAC Easikey 99
P2
P1
L1 L2
Power
Lock1
Note:
PAC Recommended cable:
7/0.2mm (0.22mm2) 4-core or
6-core unscreened cable or
CW1308 0.5dia Multipair cable.
+V2
10.5/28V
D1/SIG
n/c
VCA
0V
Channel1 Channel2 Reader Colour
Black
Yellow
White
Blue
Red
S2
R2
A2
+V1
S1
R1
A1
-V1
-V2
L3 L4
Lock2
Reader1
-V1 S1 R1 A1 +V1
Reader2
-V2 S2 R2 A2 +V2
PAC
DDA
READER
DO CLK
0V
VCA
D1/SIG
10.5-28V
*
PAC
DDA
READER
DO CLK
0V
VCA
D1/SIG
10.5-28V
*
Fail Safe 2 second
Lock Output
System Controller
The RED LED’s
must
always
be
illuminated on
both jumpers
except on lock
release.
PANEL 1
PAC -
PAC+
TR
TR
PANEL 2
PAC -
PAC+
TR
TR
0V
12V
NO
PAC
WITH
PAC
NO
PAC
WITH
PAC
NO
PAC
WITH
PAC
NO
PAC
WITH
PAC
Both Door Times
be
programed to 2 seconds
Fail Safe even if only one
reader is being used.
Must
Both Door Times
be
programed to 2 seconds
Fail Safe even if only one
reader is being used.
Must
SelectLine Controller
L
o
c
k
2
R
e
a
d
e
r2
+V
LED
RTE
DC
SIG
GND
R
e
la
y
2
N/C
COM
N/O
B
+
B
-
D
C
IN
L+
L-
L
o
c
k
1
R
e
la
y
1
R
e
a
d
e
r1
+V
LED
RTE
DC
SIG
GND
N/C
COM
N/O
L+
L-
PAC EASIKEY 1000
System Controller
The RED LED’s
must
always
be
illuminated on
both jumpers
except on lock
release.
PANEL 1
PAC -
PAC+
TR
TR
PANEL 2
PAC -
PAC+
TR
TR
PAC
DDA
READER
DO CLK
0V
VCA
D1/SIG
10.5-28V
*
0V
12V
- 24 -
Digital Video
Revision 1.08 Date: 05/01/2009
DATA 1
DATA 0
DC12V
DC12V
GND
GND
SIG 2
SIG 1
LED
LED
R +
R -
DATA 1
DATA 0
KMS
DDA
READER
DOOR 1
GND
LED
SIG1/2
12VDC
RTE2
DC2
TR1
GND2
RTE1
DC1
EMG 1&2
GND1
KMS SIMPLEKEY
Both Door ReleaseTimes
be programed to 2
seconds Fail Safe even if
only one reader is being
used.
Must
The
PAC relay
healthy indicator
must always
be on.
RED
1
2
+VE
-VE
12V
12V
0V
Sw1
Prog
Sw2
Up
Load
Sw3
Down
Load
LS2
PAC +
PAC -
LS1
LC
SA
SE
Stb-
Stb+
0V
CTS
SD
DMS
DMS
RTE/T
RTE/T
Vout
0V
SCN
Flat Programming
Button
Board Healthy
Indicator
12V
0V
SCN
SIG
CAM2 (Lobby)
12V
0V
SCN
SIG
CAM1(Panel)
+
_
1
2
pcb. 2024
Iss. 3
With DDA
facility
1 2 3
1 2 3
PAC relay healthy
indicator
Door Open Tone
Control
1 2 3
1 2 3
1 2 3
1 2 3
WITH
PAC
NO
PAC
N/C
COM
N/O
DC IN
12VDC INPUT From
Select Controller 12VDC Auxilliary Terminals
OR
Use the KMS 5Amp Power Supply
DC OUT
14.6V
Battery
-
-
-
+
+
+
-
Door 2
Alarm
N/C
COM
N/O
Door 1
Alarm
N/C
COM
N/O
Door 2
Lock
N/C
COM
N/O
Door 1
Lock
GND
RX
TX
RS232