background image

QuickStart Guide

PLFRESNEL1 MKII LED Luminaire

1 0

OPERATION AND PROGRAMMING

OPERATION AND PROGRAMMING

1. LCD Menu Operation

The PLFRESNEL1 MKII LED Luminaire’s LCD Display and Menu System provides local control for accessing all
the fixture’s status information, menu options, and settings.

Note:  

If there are multiple luminaires in a system, changes would need to be made at each LCD Menu as desired.

Upon power up, the LCD will display the main screen showing the product type/name.

Figure 6:  LCD Display and Menu System

Up/Down/Left/Right Arrow Buttons 

-

Navigates menu system and used for

Escape Button

 -

Enters menu options. Navigates

OK (Enter) Button

 -

Accesses details, activates

a field, or enters a setting
depending on the current menu item.

selecting and setting options.

(backs up) one menu level.

PRESET Button

 -

Allows the recall of

LCD Display 

-

Displays all menu parameters and

option settings. Also displays DMX512
address (DMX models only).

INTENSITY Button

 -

Allows the customization of current intensity (light
output). Note, using the LEFT and RIGHT arrow
buttons you can select each RGBW channel
individually and change their intensity using the UP
and DOWN arrows.

stored presets.

Summary of Contents for PLFRESNEL 1 MKII

Page 1: ...PLFRESNEL 1 MKII QUICK START GUIDE...

Page 2: ...ALLATION AND SET UP Top Box Connections 4 Power Requirements 4 Connecting Power 5 Connecting to the DMX512 Network 5 Mounting 6 Using Supplied C Clamp 6 Pan and Tilt Adjustments 7 Pan Adjustment 7 Til...

Page 3: ...r electric heaters d Equipment should be mounted in locations and at heights where it will not readily be subjected to tampering by unauthorized personnel e The use of accessory equipment not recommen...

Page 4: ...complete manual provides you all information related to accessories menu structures DMX channel mapping modes and care for your new luminaire Please read all instructions before installing or using th...

Page 5: ...eed 20 Amps WARNING Maximum Allowable Input Current of 20 Amps maximum power supply limit of 140 Watts Do not overload circuits Must be supplied by a branch circuit protected by a maximum 20 Amp circu...

Page 6: ...the unit The following wiring scheme is required Table 1 PLFRESNEL1 MKII LED Luminaire AC Input Connections 4 Connecting to the DMX512 Network Note Refer to Figure 1 on page 4 for DMX512 Input and Out...

Page 7: ...sing Supplied C Clamp As illustrated in Figure 3 on page 7 at yoke assembly thread clamp mounting bolt with washers installed through center clamp mounting hole at top of yoke through Top Box Assembly...

Page 8: ...o structure You should always consult and follow all local and national codes and regulations for mounting and installation of luminaire 6 Pan and Tilt Adjustments Pan Adjustment The pan adjustment of...

Page 9: ...ore information Step 2 Loosen but do not remove T Handle Tilt Lock at base of yoke assembly as shown in Figure 4 Step 3 Position luminaire to desired tilt position Step 4 Re tighten T Handle Tilt Lock...

Page 10: ...tep 2 Slide beam adjustment back for spot or forward for flood as desired Step 3 Hand tighten Beam Adjustment Knob to lock position Figure 5 Beam Adjustment Knob 2 Barndoor Assembly Selecon offers as...

Page 11: ...e 6 LCD Display and Menu System Up Down Left Right Arrow Buttons Navigates menu system and used for Escape Button Enters menu options Navigates OK Enter Button Accesses details activates a field or en...

Page 12: ...s screens may appear in reverse order a DMX Address note if fixture is UNLOCKED hit OK to change DMX address b Fixture Hours displays fixture operating hours since last reset c Fixture Power displays...

Page 13: ...o the OFF value If the fixture is unlocked User Presets can have their Color Mix and Intensity changed without restriction Note If the Color Mix of a Factory Calibrated Preset is changed by turning pr...

Page 14: ...efault is Cool White Reset Hours No Yes No Resets luminaire s operational hours Set PIN 0 0 0 0 for zeros A four digit user settable PIN code to lock the fixture Presets Protected No 5 25 5 25 Determi...

Page 15: ...MX Data Control Fixture will not respond to DMX commands Not detecting DMX data Disconnect and reconnect DMX input cable Check all DMX connections at control source and luminaire DMX data cable not wi...

Page 16: ...Road Park Royal London NW10 7QP United Kingdom Tel 44 020 8965 3209 OCEANIA 14H Vega Place Rosedale Auckland 0632 New Zealand Tel 64 9 481 0100 PLFRESNEL 1 LED Quick Start Guide Document no 02 9701 0...

Reviews: