Open-Delta Potential and Residual Ground CT Connections

Typical Wiring

Prot.

Alarm

OUT101

OUT102

OUT103

A01 A02 A03 A04 A05 A06 A07 A08 A09 A10 A11

A12

IRIG-B

IA

IB

IC

IN

Z07

Z06

Z05

Z04

Z03

Z02

Z01

Z08

TX+
TX–
RX+
RX–
SHIELD

(O

ptional)

Po

rt 4A  EI

A-

48

5

IRIG-B Time Source

 

500 m 

FO Cable**

1–12 RTDs

Optional Input Output Cards

10 RTDs 

4 Digital Inputs / 4 Digital Outputs

3 Digital Inputs / 4 Digital Outputs / 1 Analog Output

8 Analog Inputs

4 Analog Inputs / 4 Analog Outputs

Front

Port 3

TC

CC

8 Digital Inputs

(+)

(–)

52B

52A

Close

Circuit

Trip

Circuit

IN101 IN102

CONTROL INPUTS

INPUT POWER

OUTPUT CONTACTS

SEL-751A Feeder Protection Relay

A diagram for a 

four-wire wye 

connection is also 

available in the 

instruction manual.

Power Supply

110–230 Vac
24–48 Vdc
110–250 Vdc

(Optional 

485)

(Optional)

Fiber-Optic Input

Fiber-Optic Output

SEL-2600 Series 

External 

RTD Module 

(Optional)

** SEL Fiber Optic Cables

240-1506 — 1 m (3.3 ft) ST/ST
240-1507 — 5 m (16.4 ft) ST/ST
240-1508 — 15 m (49.2 ft) ST/ST
Other lengths available by request

A

C

B

Line

52

Bus

Optional Ethernet (single or dual)

Copper Wire

OR

Multimode Fiber

(+)

(–)

CURRENT INPUTS

VOLTAGE INPUTS (Optional)

TX

 

RX

 TX

 

RX

 TX

 

RX

 TX

 

RX

E0

7 E08 

E09 

E10

AF1    

AF2   

AF3   

AF4

AR

C-FLA

SH INPUT

S (

OP

TIONAL

)

To SEL-C804

Sensors

 

VA VB VC  N  VS NS VBAT 

VBAT

 E01  E02  E03  E04  E05  E06  E07  E08

V—
CAN_L
SHIELD
CAN_H
V+

GND +/H -/N

Typical Connections

Courtesy of NationalSwitchgear.com

Summary of Contents for SEL-751A

Page 1: ...et Serial Port Cover Configurable Label Kit if equipped Label Removal Tool Blank Pushbutton LED Label 198 0424 RIGHT UP Blank Target LED Label 198 0424 LEFT UP For Additional Technical Assistance Call...

Page 2: ...ONTROL INPUTS INPUT POWER OUTPUT CONTACTS SEL 751A Feeder Protection Relay A diagram for a four wire wye connection is also available in the instruction manual Power Supply 110 230 Vac 24 48 Vdc 110 2...

Page 3: ...g location and trace 2 Make smooth cut around cutout 3 Place mounting gasket around relay and insert unit into hole The photo displays optional appearance bezel 4 Fasten relay to mounting plate with i...

Page 4: ...p 3 Connect up to 2 digital inputs per application requirements to optoisolated inputs IN101 terminals 10 and 11 and IN102 terminals 11 and 12 Step 4 Connect the 3 output contacts per application requ...

Page 5: ...agram For other PT connection options refer to Section 2 of the SEL 751A manual Card Slot Z Current Inputs Card Connect phase current and neutral current inputs as shown in the typical connections dia...

Page 6: ...your choice for the connection Then you will choose which port to connect through Make sure you select the same port that you connected the cable to then click OK Step 4 Set the PC terminal emulation...

Page 7: ...LERATOR QuickSet SEL 5030 Software a Connect the relay to a PC using an SEL C234A serial or SEL C662 USB cable b Apply power to the relay c Start the ACSELERATOR QuickSet software program and establis...

Page 8: ...tering Group 1 Logic Settings Enable and enter SELOGIC equations settings as needed by the application Repeat above steps for Group 2 and 3 settings if required by the application Global Settings Revi...

Reviews: