Sel 3355-2 Manual Download Page 12

12

© 2018–2021 by Schweitzer Engineering Laboratories, Inc. All rights reserved.

All brand or product names appearing in this document are the trademark or registered
trademark of their respective holders. No SEL trademarks may be used without written
permission. SEL products appearing in this document may be covered by U.S. and Foreign
patents.

Schweitzer Engineering Laboratories, Inc. reserves all rights and benefits afforded under
federal and international copyright and patent laws in its products, including without lim-
itation software, firmware, and documentation.

The information in this document is provided for informational use only and is subject to
change without notice. Schweitzer Engineering Laboratories, Inc. has approved only the
English language document.

This product is covered by the standard SEL 10-year warranty. For warranty details, visit
selinc.com or contact your customer service representative.

*PDS3355-04*

2350 NE Hopkins Court • Pullman, WA 99163-5603 U.S.A.
Tel: +1.509.332.1890 • Fax: +1.509.332.7990
selinc.com • [email protected]

SEL-3355-2 Data Sheet

Date Code 20211229

Summary of Contents for 3355-2

Page 1: ...he need for external inverters and enhance system reliability availability and serviceability You can install software from SEL and third party software ven dors to customize the SEL 3355 2 for your s...

Page 2: ...The SEL 3355 2 supports as many as four standard PCIe form factor expansion cards and one 32 bit PCI card enabling you to customize the system I O to meet your application needs Choose from a selectio...

Page 3: ...ea net works LANs for control data or engineering access Time The SEL 3390S8 serial expansion card accepts IRIG B time code input for precise time input and distribution to connected devices EIA 232 E...

Page 4: ...re 4 SEL 3355 2 as Remote Read Only Domain Controller Performing Central Authentication Using LDAP Disturbance Recording System for PRC 002 2 Figure 5 Reliable Hardware for Running Your Disturbance Re...

Page 5: ...Ds for your custom application i USB Ports Two easily accessible ports to connect USB 3 1 peripherals o SATA Drive Bay Removable cover plate enables easy access to SATA drives from the front panel i y...

Page 6: ...SEL 3355 2 Data Sheet Schweitzer Engineering Laboratories Inc 6 Product Dimensions Figure 9 SEL 3355 2 Dimensions for Rack and Panel Mount Models...

Page 7: ...Hz base 2 8 GHz turbo Cache 1 MB L2 8 MB L3 Intel Xeon E3 1505M Quad Core Speed 2 8 GHz base 3 7 GHz turbo Cache 1 MB L2 8 MB L3 RAM 4 64 GB DDR4 ECC PC4 17000 2133 MHz Chipset Intel CM236 Chipset Exp...

Page 8: ...SEL 3390S8 Expansion Cards As many as 24 additional EIA 232 422 485 ports RJ45 connectors 300 to 921600 bps Note See the SEL 3390S8 instruction manual for additional information Meets EIA TIA 562 Spec...

Page 9: ...min Size 12 18 AWG Tightening Torque Minimum 0 6 Nm 5 in lb Maximum 0 8 Nm 7 in lb Crimp Ferrule Recommended Mounting Ear Tightening Torque Minimum 0 18 Nm 1 6 in lb Maximum 0 25 Nm 2 2 in lb Groundi...

Page 10: ...14 2009 Severity Level 5 cycles 1 C per minute ramp 40 to 60 C E3 1505M CPU 40 to 75 C E3 1505L CPU Cold Operational IEC 60068 2 1 2007 Severity Level 16 hours at 40 C Cold Storage IEC 60068 2 1 2007...

Page 11: ...pset Heaterb cold startup 5 C 41 F continuous operation 0 C 32 F continuous operation 40 C 40 F N A 0 W 0 W N A 5 W 20 W 90 W 10 W 40 W a Minimum 0 load on all components minimum power consumption sta...

Page 12: ...d international copyright and patent laws in its products including without lim itation software firmware and documentation The information in this document is provided for informational use only and...

Reviews: