READ THE FOLLOWING WARNINGS BEFORE INSTALLING 

OR PERFORMING MAINTENANCE ON THE PUMP. 

I

 

WARNING:  BEFORE  DOING  ANY  WORK  ON  THE  PUMP,  ALWAYS  FIRST  DISCONNECT  THE 

POWER SUPPLY CABLE. 

I

 

WARNING

WE  RECOMMEND  INSTALLING  THE  PUMP  IN  A  VERTICAL  POSITION  TO  ENSURE 

PROPER OPERATION. 

I

 

ATTENTION: PRODUCT INTENDED FOR PROFESSIONAL USE BY SKILLED PERSONNEL.

 

I

 

ATTENTION: MAINTENANCE WORK ON THE PUMP MUST BE CARRIED OUT BY AUTHORISED AND 

TRAINED PERSONNEL ONLY.

 

 

-

 

H

2

SO

4

 SULPHURIC ACID

 

All the pumps are tested with water. Before dosing chemical products that may react 

with water, dry all the internal parts of the plumbing thoroughly.

 

-

 

Install the pump in a zone where the environment temperature does not exceed 40

º

C and the relative humidity is below 

90%. The pump has an IP65 protection level. Avoid installing the pump directly exposed to sunlight. 

-

 

Install the pump so that any inspection and maintenance operations are easy to carry out, then secure the pump firmly in 
order to prevent excessive vibrations. 

-

 

Check that the power supply available in the network is compatible with that indicated on the pump label. 

 
 
 

WIRING

 

 

Input A 

= Power 

supply 100 - 240 Vac 
(50-60 Hz) 
 

Input 

B

 =  

Pulses free from 
voltage 
(pulse emission meter 
or Hall sensor) 

 

Input C

 = Level 

control probe input 
 

The pump must be connected to a 
power supply that complies with the 
information indicated on the label on 
the side of the pump. Failure to 
respect these limits may cause 
damage to the pump itself. 

The pumps have been designed to 
absorb small over voltages. 
Therefore, in order to prevent the 
pump from being damaged, it is 
always preferable to ensure that the 
pump does not have a power source 
shared with electrical appliances that 
generate high voltages. 
 

Connection with the three-phase 
380V line should only be made 
between phase and neutral. 

Connections MUST NOT be made 
between phase and ground. 

1 2 3 4 5 6

F

 

Output 
voltage 10 
Vcc 

Hall sensor or similar input  
(output voltage 10 Vcc; maximum 
current 5 mA) 

Signal 

GND 

Not used. 

Pulses free from voltage 
(pulse emission meter; dry contact: on-off, 
maximum frequency 80Hz) 

Level control probe input  
(Dry contact: on-off) 

Fuse: 2A 250V T 5x20.  

Summary of Contents for KOMPACT AMC 200

Page 1: ...EM00136401 Rev 1 0 EN RU KOMPACT AMC INSTALLATION MANUAL РУКОВОДСТВО ПО УСТАНОВКЕ И ЭКСПЛУАТАЦИИ ...

Page 2: ...EM00136401 Rev 1 0 ...

Page 3: ...tact with the liquid to be dosed Check the rating plate of the main features of your pump 1 Adjustments area 2 Dosing head 3 Priming valve 4 Delivery connector 5 Suction connector 6 Base fixing bracket optional We recommend checking the chemical compatibility between the product and the materials in contact PUMP HEAD MATERIALS Pump body PVDF T Valves PVDF T Balls Ceramic Diaphragm PTFE SPECIFICATI...

Page 4: ...prevent excessive vibrations Check that the power supply available in the network is compatible with that indicated on the pump label WIRING Input A Power supply 100 240 Vac 50 60 Hz Input B Pulses free from voltage pulse emission meter or Hall sensor Input C Level control probe input The pump must be connected to a power supply that complies with the information indicated on the label on the side...

Page 5: ...C it s possible to set through a jumper in the pulses input shown in the figure two different frequency settings with the regulation potentiometer at 100 100 without the jumper in the pulses input The pump doses at a maximum frequency of 160 strokes minute 20 with the jumper in the pulses input The pump doses at a maximum frequency of 32 strokes minute PLUMBING CONNECTIONS 13 4 6 3 12 5 2 11 6 4 8...

Page 6: ... Once you are sure that the pump is completely full of liquid you can close the connector and the pump will begin to dose TROUBLESHOOTING Problem Possible Cause Solution The pump is working properly but the dosage is interrupted Blocked valve Clean the valves or replace them if it is not possible to remove the build ups Excessive suction height Position the pump or tank so as to reduce the suction...

Page 7: ...tically distributes the n strokes measuring the time between two successive pulses for a maximum of 60 seconds after which period the pump once again doses at maximum speed resetting the time count The pump also has a memory alarm which is triggered if it receives other external signals water meter pulse sender during the dosage of the n strokes Below are some examples of operation Potentiometer N...

Page 8: ...х данных основные характеристики вашего насоса 1 Рукоятка регулировки 2 Дозирующая головка 3 Клапан закачки 4 Нагнетательный штуцер 5 Всасывающий штуцер 6 Опора основание доп оборудование Рекомендуем выполнить проверку на химическую совместимость дозируемого продукта с находящимися с ним в контакте материалами насоса МАТЕРИАЛЫ ВХОДЯЩИЕ В СОСТАВ ГОЛОВКИ НАСОСА Корпус насоса Поливинилденхлорид PVDF ...

Page 9: ...ходе в установку должны быть совместимы с данными приведенными на табличке насоса ЭЛЕКТРИЧЕСКИЕ ПОДКЛЮЧЕНИЯ Вход A Питание 100 240 Vac 50 60 Гц Вход B Беспотенциальные импульсы счетчик генератор импульсов или датчик Холла Вход C Вход зонда контроля уровня Насос должен быть подключен к питанию соответствующему указанному в табличке на боковой стороне насоса Несоблюдение этих указаний может привести...

Page 10: ...еля в положение C и перемычки в контактах 2 и 4 показано на рисунке возможно установить два различных диапазона регулировки при положении ручки на 100 100 без перемычки в контактах Насос дозирует на максимальной частоте 160 впрысков мин 20 с перемычкой в контактах Насос дозирует на максимальной частоте 160 впрысков мин ГИДРАВЛИЧЕСКИЕ ПОДКЛЮЧЕНИЯ 13 4 6 3 12 5 2 11 6 4 8 4 6 6 4 3 14 5 10 9 7 5 5 1...

Page 11: ...сос полностью заполнен жидкостью закрыть штуцер насос готов к дозированию РАЗРЕШЕНИЕ ПРОБЛЕМ Неисправность Возможная причина Решение Насос работает нормально но дозирование прекращено Засорение клапанов Очистить клапаны или заменить их если невозможно удалить накипь Чрезмерная высота всасывания Установить насос или бак таким образом чтобы уменьшить высоту всасывания Слишком вязкая жидкость Уменьши...

Page 12: ...тически распределяет впрыски измеряя время между двумя принятыми импульсами максимум 60 секунд после которых счётчик обнуляется и насос снова дозирует на максимальной частоте Насос так же оснащён аварийным режимом по памяти который активируется если внешний импульс получен раньше чем насос отработал предыдущие n впрысков Ниже несколько примеров Потенциометр N впрысков импульс 100 10 50 5 10 1 Оран...

Reviews: