background image

1x
0x

=
=
=

o.k.

LOW

STOP

2x

1x

0x

=

=

ERROR

 ... [10 sec.] ...

 

 

... [10 sec.] ...

 

 ...

 

 

... [10 sec.] ...

 

Messages from LED-lamps and operators lighting

The TS Solar/TS Akku is equipped with an automatic diagnostic 
system which provides information via the external LED-lamps.
These messages are:

Status Messages

In intervalls of 10 seconds the yellow and green LED-lamps give 
information about the battery status and if the battery is being 
rechared or not.

Yellow LED  (Recharging of the battery)

0 blinks

The battery is not being recharged.
TS Solar I: no energy from the solar panel (e.g. at night)
TS Akku I: no 230V power supply

1 blink

The battery is being recharged
TS Solar I: energy is received from the solar panel
TS Akku I: 230V are coming from the net

Green LED (Status of the battery)

0 blinks

The battery has no sufficient voltage to run the operator - the
electronic disables the operator until the battery was recharged. 
It will then automatically enable the operator.

1 blink

The batteries voltage is low, the operator can only be used for 
a restricted number of runs. When this state is reached, the 
operators light will be blinking during the run.

2 or 3 blinks

The battery is full and provides sufficient voltage to run the 
operator.

Error Messages

Error Messages are provided by the red LED lamp „Diag“ on the 
electronics together with the red LED lamp on the outside of the 
housing. With some of the messages the operators lighting will be 
blinking simultaneousely.

Messages from the red LED-lamp and the 
operators lighting

2 blinks

The limits cannot be reached though neither an obstacle was  
nor a damage on the hall-sensor was detected. There is even-
tually a damage on the operators‘ mechanics - the electronic 
disables the operator.

5 blinks

The microprocessor has lost its data; try to execute the learning 
cycle. If this does not work, then the electronics needs to be 
exchanged.

6 blinks

No information can be written to the microprocessor. The 
electronics disables itself and needs to be exchanged.

7 blinks

A relais is damaged - The electronics disables itself and needs to 
be exchanged.

8 blinks

General fault. The electronics disables itself and needs to be 
exchanged.

9 blinks

Error with the detection of Hall Sensor signals. Either the mo-
tors‘ Hall Sensor or the electronics is faulty.

 

Additional Messages only from the red LED lamp

3 blinks

Photo Cell - either an obstacle is blocking the photo cell or the 
photo cell is damaged. The error message will be cancelled, 
when the error was eliminated.

4 blinks

Error on the 8k2 connector (Safety Beam/Hatch Door) - ei
Fehler an der 8k2-Auswertung (Schlupftür/Kontaktleiste) - either 
an obstacle is blocking the Safety Beam/Hatch Door or one of 
the devices is faulty. The error message will be cancelled, when 
the error was eliminated.

red

yellow

green

IMPORTANT ADVISE!

Once the battery has reached a critical discharge level, the 
operators light will start blinking during operation; if it is 
discharged further, the light will switch off.
 
Dependant on the usage of battery capacity (door size 
and weight) the operation might be stopped during an 
opening or closing procedure!

The operator can be used again, once the battery was 
recharged (from the net or solar panel). The electronics 
will then enable the operator for use automatically when 
the battery has reached a sufficient charging level. Until 
that point of time, the door needs to be operated 
manually (please refer to chapter „Emergency Release“).

Summary of Contents for TS Solar I

Page 1: ...carefully the security advises on the following pages Please fill in the serial number of your operator You will find the serial number on your operator Factory controlled by The number describes the...

Page 2: ...y not be aware that the door has started moving Always watch the moving door and keep persons away until the garage door is either completely opened or closed Do not leave any obstacles in the garage...

Page 3: ...unexpected obstacle within the doors range Please also refer to the Safety Instructions on page 2 The operator registers an obstacle by touching it the garage door hits the obstacle and reverses to s...

Page 4: ...tions for programming Programming Transmitter and Receiver To use a hand transmitter it must first be registered programmed by the receiver Only one hand transmitter button can be used for one receive...

Page 5: ...n the lower the range will be Building materials of the garage In a garage made of concrete and steel you might reach a lower range than in an ordinary garage build of stone The more steel was used fo...

Page 6: ...should occur then the operators light will start blinking when you try to activate it The blinking light refers to errors caused by external devices the fol lowing steps only need to be followed if an...

Page 7: ...d There is even tually a damage on the operators mechanics the electronic disables the operator 5 blinks The microprocessor has lost its data try to execute the learning cycle If this does not work th...

Page 8: ...batterie is recharged Especially in winter with only little daily sunlight the recharging procedure for a flat batterie might take 3 to 6 days when being dependant on the solar panel only Whether the...

Reviews: