1x
0x
=
=
=
o.k.
LOW
STOP
2x
1x
0x
=
=
ERROR
... [10 sec.] ...
... [10 sec.] ...
...
... [10 sec.] ...
Messages from LED-lamps and operators lighting
The TS Solar/TS Akku is equipped with an automatic diagnostic
system which provides information via the external LED-lamps.
These messages are:
Status Messages
In intervalls of 10 seconds the yellow and green LED-lamps give
information about the battery status and if the battery is being
rechared or not.
Yellow LED (Recharging of the battery)
0 blinks
The battery is not being recharged.
TS Solar I: no energy from the solar panel (e.g. at night)
TS Akku I: no 230V power supply
1 blink
The battery is being recharged
TS Solar I: energy is received from the solar panel
TS Akku I: 230V are coming from the net
Green LED (Status of the battery)
0 blinks
The battery has no sufficient voltage to run the operator - the
electronic disables the operator until the battery was recharged.
It will then automatically enable the operator.
1 blink
The batteries voltage is low, the operator can only be used for
a restricted number of runs. When this state is reached, the
operators light will be blinking during the run.
2 or 3 blinks
The battery is full and provides sufficient voltage to run the
operator.
Error Messages
Error Messages are provided by the red LED lamp „Diag“ on the
electronics together with the red LED lamp on the outside of the
housing. With some of the messages the operators lighting will be
blinking simultaneousely.
Messages from the red LED-lamp and the
operators lighting
2 blinks
The limits cannot be reached though neither an obstacle was
nor a damage on the hall-sensor was detected. There is even-
tually a damage on the operators‘ mechanics - the electronic
disables the operator.
5 blinks
The microprocessor has lost its data; try to execute the learning
cycle. If this does not work, then the electronics needs to be
exchanged.
6 blinks
No information can be written to the microprocessor. The
electronics disables itself and needs to be exchanged.
7 blinks
A relais is damaged - The electronics disables itself and needs to
be exchanged.
8 blinks
General fault. The electronics disables itself and needs to be
exchanged.
9 blinks
Error with the detection of Hall Sensor signals. Either the mo-
tors‘ Hall Sensor or the electronics is faulty.
Additional Messages only from the red LED lamp
3 blinks
Photo Cell - either an obstacle is blocking the photo cell or the
photo cell is damaged. The error message will be cancelled,
when the error was eliminated.
4 blinks
Error on the 8k2 connector (Safety Beam/Hatch Door) - ei
Fehler an der 8k2-Auswertung (Schlupftür/Kontaktleiste) - either
an obstacle is blocking the Safety Beam/Hatch Door or one of
the devices is faulty. The error message will be cancelled, when
the error was eliminated.
red
yellow
green
IMPORTANT ADVISE!
Once the battery has reached a critical discharge level, the
operators light will start blinking during operation; if it is
discharged further, the light will switch off.
Dependant on the usage of battery capacity (door size
and weight) the operation might be stopped during an
opening or closing procedure!
The operator can be used again, once the battery was
recharged (from the net or solar panel). The electronics
will then enable the operator for use automatically when
the battery has reached a sufficient charging level. Until
that point of time, the door needs to be operated
manually (please refer to chapter „Emergency Release“).