Printed Circuit Board: Adjustments and Connections
Programming the Soft-Modes
The RP60 is shipped with factory pre-set values for the Soft-
Modes; if the learning cycle is run without any changes to the
factory-settings, then the pre-set values will be programmed
automatically.
The BOTTOM Soft-Stop
The length of the BOTTOM Soft-Stop may be changed during the
first run of the learning-cycle in closing direction.
-
Extending
the BOTTOM Soft-Stop is recommended, if the
garage door slams on closing.
-
Reducing or disabling
the BOTTOM Soft-Stop is recommen-
ded, when the bottom of the garage door does not close comple-
tely. Expecially when mechanical spring-locks are installed, these
might not engage. When the BOTTOM Soft-Stop is disabled, the
garage door reaches the closing position with a higher speed. This
gives the door a higher momentum and the bottom can fall into
the doors‘ frame - the locks can then engage.
Programming the BOTTOM Soft-Mode
The length of the soft-stop can be adjusted during the first au-
tomatic measurement-run in closing direction. Please proceed as
described below:
1. Start the learning cycle (refer to page 11)
2. the operator runs in closing direction with low speed
3. press the LERN/LEARN button and keep it pressed - the operator
is now increasing the speed
4. release the LERN/LEARN button at the position where the soft-
stop shall begin
(the operator will safe this position as the
beginning of the BOTTOM soft-stop)
If the Soft-Stop is to be disabled, then the LEARN button must be
pressed until the door is completely closed.
5. the operator will reduce speed with a short delay and then
reach the closing position
6. the operator will procede with the remaining measurement-
runs
When the operators‘ light stops blinking, all measured values
are saved in the memory - the BOTTOM soft-stop now is in the
programmed position.
Enabling the TOP Soft-Modes
The RP60 will start the closing procedure from OPENING posi-
tion with slow speed (e.g. TOP Soft-Mode). Dependant on the
performance of the garage door it might be necessary to enable
this Soft-Mode, especially when the operator reverses during that
period (e.g. pressure detection).
Procedure for Enabling the TOP Soft-Mode
Remove the jumper „KRAFT/PRESSURE“ before starting the
learning cycels and leave it removed until the learning cycles are
completed - the TOP Soft-Mode then is enabled.
After the learning cycles the Jumper „Kraft/Pressure“ fulfills its‘
normal function („Normal Force/Higher Force during CLOSING
Soft-Stop“ as to page 10) and can be replaced.
TIP: should you decide to remove the jumper, then plug it
back onto one pin only - so it remains available on the P.C.B.
for later use.
Quick Reference „Programming the BOTTOM Soft-Mode“
1.) During the first learning
cycle in CLOSING direction
Keep the LERN/LEARN button
pressed during the first run in
CLOSING direction and keep it
pressed -the operator increases
speed
2.) The operator is running
in CLOSING direction with
increased speed
Release the LERN/LEARN button
at the position where the soft-
stop shall start in future.
If the LEARN button is kept
pressed until the door is
completely shut, then the
soft-stop will be disabled.
3.) The operator reaches the CLOSED position. It will proceed
with the learning-cycle (two more runs) before finishing the pro-
gramming. The CLOSING Soft-Stop will then be set as to your
adjustments.
Quick Reference „Enabling the TOP Soft-Mode“
1.) Remove the Jumper KRAFT/PRESSURE before starting the
learning cycles
2.) Start the learning cycle
3.) After the learning cycles are completed the jumper can be
replaced (dependant on the required function, as to page 10)
TOP soft-mode