background image

A3. Eyepiece

B2. Diopter

adjuster

A9. Notch for

attachment

A7. Clamp

B3. Aperture

diaphragm cover

B4. Condenser

Adjusting screw

(left & right)

A8.  Condenser

A10. Filter

B5. Field diaphragm 

revolver

B6. Condenser

thumb screw

B7. B8.  Stage moving knobs

B9. Potentiometer

A11. Conden

set holder

A6. Mechanical

stage

A5. Objective

A1. Body

A4. Nosepiece

B1. Head thumb screw

A3. Eyepiece

1. Parts Name

Fig. 1-1

1

Summary of Contents for Microlux IV

Page 1: ...Microlux IV LED Operations Manual...

Page 2: ...3433 Tree Court Industrial Blvd St Louis MO 63122 800 489 2282 314 968 2282 Email micro seilerinst com www seilerinst com...

Page 3: ...Contents 1 Parts Name 1 2 Specification 2 3 Installation 3 4 Operation 4 5 Installation Operation for Attachments 5 6 Maintenance 5 7 Troubleshooting 10 8 Outfits 11...

Page 4: ...r B4 Condenser Adjusting screw left right A8 Condenser A10 Filter B5 Field diaphragm revolver B6 Condenser thumb screw B7 B8 Stage moving knobs B9 Potentiometer A11 Conden set holder A6 Mechanical sta...

Page 5: ...er A12 Handle A13 Power Input A14 Fuse A15 Lamp Plate B1 Head thumb screw B2 Diopter adjuster B3 Aperture diaphragm lever B4 Condenser adjusting screw B5 Field diaphragm revolver B6 Condenser thumb sc...

Page 6: ...m X Y travel 55mm X 78mm 2 3 6 Focusing systems Coaxial coarse and fine focusing knobs Coarse stroke 25mm fine division 2 m Condenser up down range 25mm 2 3 7 Condenser Abbe condenser N A 1 25 Adjusta...

Page 7: ...lter Fig 2 3 Installation Please install the microscope as follows Installation Process see Figure 3 on page 5 1 Installing Lamp LED is factory installed 2 Installing binocular head Loosen B1 binocula...

Page 8: ...d Turn B10 condenser focusing screw and raise the condenser to working position 6 Installing blue filter or the other attachment If blue filter will be used the installation should be done before proc...

Page 9: ...clamp and put the sample on it turn B7 B8 stage knobs to put the sample into light path Turn A4 nosepiece put 10x objective into light path turn B13 B14 coarse and fine focus knobs Adjust A2 head to m...

Page 10: ...ase tension u Don t turn left and right coarse and fine focusing knobs in different directions with power at the same time if so the focusing system will be damaged Fig 6 4 Interpupillary distance and...

Page 11: ...move the image to the center of field d Put 40x objective into light path turn B5 field diaphragm revolver to make the field diaphragm image bigger than field diaphragm Please center it again if the i...

Page 12: ...ith hand Dust on lens should be cleaned by soft brush absorbent cotton or lens paper with a mixture of alcohol and ether proportion 1 4 6 1 2 Alcohol and ether are flammable please keep them away from...

Page 13: ...occurs please refer to the following chart for some common resolutions Trouble Power on but no light Brightness of view field isn t enough or uneven Cause Plug is unreliable Bulb is broken Fuse is br...

Page 14: ...adjusted correctly Diopter isn t adjusted correctly Trouble Brightness of view field isn t enough or is uneven Image isn t clear contrast or definition isn t enough One side of image is dark or image...

Page 15: ...3601 www seilerinst com Microscope Division Manager Dane Carlson ext 365 dcarlson seilerinst com Corporate Sales Representative Nicole Rasch ext 345 nrasch seilerinst com Technical Product Information...

Page 16: ......

Reviews: