background image

English

9

English

8

•  To check the winding state of the mainspring, refer to “HOW TO READ THE POWER 

RESERVE INDICATOR “ on page 12.

•  There is no need to turn the crown further when the mainspring is fully wound. But 

the crown can be turned without damaging the watch mechanism.

•  Once the watch is wound up fully, it operates for about 41 hours.
•  If the watch is used without being wound up fully, gain or loss of the watch may 

result.  To avoid this, wear the watch for more than 10 hours a day.  If the watch is 

used without wearing on the wrist (if it is used on the desk like a clock, for example), 

be sure to wind it up fully every day at a fixed time.

•  If the watch has stopped with the mainspring unwound, winding the mainspring 

with the crown will not start the watch immediately.  This is because the main-

spring torque (force) is low at the beginning of its winding due to the characteristics 

of mechanical watches.  The second hand starts to move when a certain degree 

of strong torque is reached after the mainspring has been wound up.  However, 

swinging the watch from side to side to forcibly turn the balance can start the 

watch sooner.

•  Check that the watch is operating, and then set the time and date. 
•  The watch is provided with a date function and is so designed that the date 

changes once every 24 hours.  The date changes around 12 o’clock midnight.  If 

AM/PM is not properly set, the date will change around 12 o’clock noon.

HOW TO SET THE TIME AND DATE

CAUTION

•  Do not set the date between 9:00 p.m. and 1:30 a.m.  If you do so, the date 

may not change properly / it may cause a malfunction. 

1.  Pull out the crown to the first click.  (The second 

hand continues moving and the accuracy of the 

watch is unimpaired.)

2.  The date can be set by turning the crown 

counterclockwise.  Turn it until the previous 

date appears.

Ex.)   If today is the 5th of the month, first set the date 

to ”4”  by turning the crown counterclockwise. 

Summary of Contents for SSA392J1

Page 1: ...Cal 4R57 INSTRUCTIONS P 3 BEDIENUNGSANLEITUNG S 21 INSTRUCTIONS P 41 ISTRUZIONI P 61 INSTRUCCIONES P 81 INSTRUÇÕES P 101 ИНСТРУКЦИИ P 121 141 ...

Page 2: ...s optimales veuillez lire attentivement cette brochure avant d utiliser la montre Conservez ce manuel pour vous y référer en cas de besoin Grazie di aver acquistato questo nuovo Orologio Automatico SEIKO Cal 4R57 Per poter utilizzare l orologio al massimo delle sue prestazioni leggere attentamente questo manuale di istruzioni prima di passare all uso dell orologio stesso e conservarlo poi per qual...

Page 3: ...ies according to conditions of use time period that the watch is worn on the wrist temperature environment hand movement and winding state of the mainspring When the watch is affected by strong magnetism it temporarily gains or loses time If the watch encounters a strong magnetic field the parts of the watch may be magnetized In this case repairs such as removal of magnetism are required Contact t...

Page 4: ...arer s arm winds the mainspring of the watch If your watch is completely stopped it is recommended that you manually wind the mainspring by turning the crown How to manually wind the mainspring by turning the crown 2 Wind the mainspring until the power reserve indicator shows a full wound state The second hand will start moving 3 Set the time and date before putting the watch on your wrist If your...

Page 5: ...of its winding due to the characteristics of mechanical watches The second hand starts to move when a certain degree of strong torque is reached after the mainspring has been wound up However swinging the watch from side to side to forcibly turn the balance can start the watch sooner Check that the watch is operating and then set the time and date The watch is provided with a date function and is ...

Page 6: ... than 31 days Ex To adust the date in the a m period on the first day of a month following a 30 day month 1 The watch displays 31 instead of 1 Pull out the crown to the first click 2 Turn the crown to set the date to 1 and then push the crown back in to the normal position CAUTION Do not set the date between 9 00 p m and 1 30 a m If you do the date may not change properly it may cause a malfunctio...

Page 7: ...tra time When the mainspring is fully wound the crown can be turned further without damaging the mainspring itself The mainspring of the watch employs a slipping mechanism to prevent the mainspring from over winding The orientation of the power reserve indicator may slightly vary depending on the model Power reserve indication is intended only as a guide Thus the power reserve indicator may or may...

Page 8: ... little clearance around your wrist to ensure proper airflow Prolonged and or repeated contact with the band may cause skin irritation or dermatitis for those susceptible Possible causes of dermatitis Allergic reaction to metals or leathers Rust contamination or perspiration accumulated on the watch case or band If you should develop any allergic symptoms or skin irritation immediately stop wearin...

Page 9: ... GUARANTEE AND REPAIR Please contact the retailer the watch was purchased from or SEIKO CUSTOMER SERVICE CENTER for repair or overhaul Withintheguaranteeperiod pleasepresentthecertificateofguaranteetoreceive repair services Guarantee coverage is provided in the certificate of guarantee Please read carefully and retain it TROUBLESHOOTING Problem Possible causes Solutions The watch stops operating T...

Page 10: ...atches is indicated by the daily rates of one week or so The accuracy of mechanical watches may not fall within the specified range of time accuracy because of loss gain changes due to the conditions of use such as the length of time during which the watch is worn on the wrist arm movement whether the mainspring is wound up fully or not etc The key components in mechanical watches are made of meta...

Page 11: ...600 3 Operational temperature range Between 10 ºC and 60 ºC Between 14 ºF and 140 ºF 4 Continuous operating time More than approx 41 hours 5 Driving system Automatic winding type with manual winding mechanism 6 Jewels 29 jewels 7 Magnetic resistance 4 800 A m 60 gauss The specifications are subject to change without prior notice for product improvement ...

Reviews: