Inspection and adjustment by disassembly and cleaning (overhaul) of this 
watch will be performed by SEIKO. When you take the watch to the re-
tailer from whom it was purchased, request that the watch be inspected and 
overhauled by SEIKO.
We suggest that you have your watch checked by SEIKO every 3 to 4 years 
for long-time use of your watch.

※  The movement of this watch has a structure that consistent pressure is applied on its pow-

er-transmitting wheels. To ensure these parts work together properly, periodic inspection 
including cleaning of parts and movement, oiling, adjustment of accuracy, functional check 
and replacement of worn parts is needed.

Inspection and adjustment by disassembly and cleaning (overhaul) within 3 to 4 years from the 
date of purchase is highly recommended for long-time use of your watch.
Contact the retailer from whom the watch was purchased for inspection and adjustment by dis-
assembly and cleaning (overhaul) of your watch. Make sure that the gasket and push pin will be 
also replaced with new ones.

・ For  any  questions  or  concerns,  contact  the  "CUSTOMER  SERVICE 

DEPARTMENT" of SEIKO WATCH CORPORATION.

●Inspection and adjustment by disassembly and cleaning (overhaul)

・ If the watch is left in a temperature below − 10℃ or above + 60℃ for a 

long time it may function improperly or stop operating.

・ Do not leave the watch in a place where it will be subjected to strong 

magnetism (for example, near television sets, loudspeakers or magnetic 
necklaces).

・ Do not leave the watch where there is strong vibration.
・ Do not leave the watch in a dusty place.
・ Do not expose the watch to gases or chemicals.

(Ex.: Organic solvents such as benzene and thinner, gasoline, nail polish, 
cosmetic spray, detergent, adhesives, mercury, and iodine antiseptic solu-
tion.)

・ Do not leave the watch in close contact with hot spring water, or do not 

keep it in a drawer having insecticides inside.

●PLACES TO KEEP YOUR WATCH

96

97

Solution

Wind the mainspring and reset the time. While you are wearing the watch or when you take it off, check the re-

maining power shown by the power reserve indicator and wind the mainspring if necessary.

Wear the watch for an extended period of time, or when taking off the watch, turn the crown to wind the main-

spring if the remaining power shown by the power reserve indicator is not sufficient for the next use.

Return the watch to a normal temperature so that it works accurately as usual, and then reset the time. The watch has been 

adjusted so that it works accurately when it is worn on your wrist under a normal temperature range between 5℃ and 35℃ .

Correct this condition by moving and keeping the watch away from the magnetic source. If this action does not 

correct the condition, contact the retailer from whom the watch was purchased.

Reset the time.  If the watch does not return to its normal accuracy after resetting the time, contact the retailer 

from whom the watch was purchased.

Contact the retailer from whom the watch was purchased.

If the watch is left at a temperature below 0℃ , it may stop if the power reserve indicator is showing less than 

one-sixth of the power reserve.  In such a case, turn the crown to wind the mainspring.

It takes several seconds before the adjustment function starts working. Set the time after the second hand moves 

for approximately 30 seconds to set the time correctly.

Advance the hour hands for 12 hours to correctly set the time and date.

■TROUBLESHOOTING

Trouble

Possible cause

The watch stops operating.

(The chronograph hands do not move.)

The power supplied by the mainspring has been consumed.

Even  though  you  wear  the  watch  every  day,  the 

power reserve indicator does not move up.

The watch is worn on your wrist only for a short period of 

time, or the amount of arm movement is small.

The watch temporarily gains or loses time.

The watch has been left in extremely high or low tempera-

tures.

The  watch  has  been  left  close  to  an  object  with  a  strong 

magnetic field.

You drop the watch, hit it against a hard surface, or wear it while 

playing active sports.  The watch is exposed to strong vibrations.

The inner surface of the glass is clouded.

Moisture has entered the watch because the gasket has deteriorated.

The  watch  stops  even  though  the  power  reserve 

indicator is not showing  "0."

The watch has been left at a temperature below 0℃ .

Right after starting the watch, it seems that the second 

hand moves more quickly than usual when setting the time.

When  starting  the  watch,  it  takes  a  little  time  before  the 

adjustment function starts working (this is not a malfunction).

The date changes during daytime.

AM/PM is not correctly set.

Refer to "How to manually wind the mainspring by turning the crown" on page 61. Refer to "How to set the time" on page 64.

※ In the event of any other problem, please contact the retailer from whom the watch was purchased.

Summary of Contents for Spring Drive Chronograph 9R86

Page 1: ... jp ...

Page 2: ... to the self winding mechanism which uses the natural motion of the wearer s arm as a power source to wind its mainspring the watch is equipped with the manual wind ing mechanism which is convenient to wind the mainspring when you start using the watch The watch keeps working for approximately 72 hours three days when the mainspring is fully wound The watch features the power reserve indicator to ...

Page 3: ...s positioned for calendar set ting time difference adjustment 2 Screw lock type crown is positioned for time setting 56 57 SCREW LOCK TYPE CROWN AND BUTTON How to use the screw lock type crown The watch features a screw lock mechanism that can securely lock the crown and but tons to prevent any operational errors when they are not being operated How to unlock the screw lock type crown How to lock ...

Page 4: ... wrist the motion of the wearer s arm winds the mainspring of the watch When first using a stopped watch it is recommended that you manually wind the mainspring by turning the crown How to manually wind the mainspring by turning the crown In order to set the time and calendar after winding the mainspring manually do not relock the crown but continue the procedures Refer to How to set the time and ...

Page 5: ...or lets you know the winding state of the main spring 64 65 HOW TO SET THE TIME AND CALENDAR To set the time and calendar set the 24 hour hand and minute hand first and then set the hour hand and calendar How to set the time 1 Make sure that the mainspring is sufficiently wound and the watch is working When setting the date and time ensure that the watch is working 3 Pull out the crown to the seco...

Page 6: ... you to set the date with a smaller adjustment Turn the crown slowly checking that the hour hand moves in one hour increments When adjusting the hour hand the other hands may move slightly However this is not a malfunction 68 69 How to set the calendar Two full rotations of the hour hand will change the date for one day The date advances one day by turning the hour hand two full rotations clockwis...

Page 7: ...e with a different time from where you live you can conveniently set the watch to indicate the local time in the different time zone area without stopping the watch The hour hand indicates the time of the place where you currently are while the 24 hour hand in dicates the time of the place of origin The calendar works in conjunction with the movement of the hour hand If the time difference is corr...

Page 8: ...nolulu 19hours 10hours MidwayIslands 20hours 11hours There are time zone differences based on time offsets from Coordinated Universal Time UTC which has been internationally adopted The world is divided into 24 time zones and neighboring time zones have a one hour time difference so that they correspond to the rotation of the earth which makes one full rotation in 24 hours 1 day In some regions of...

Page 9: ...ition press the RESET button Be careful not to pull out the crown while the chronograph second hand is moving The chronograph second hand will be stopped in the middle of the measurement 80 81 How to use the chronograph stopwatch function 1 Make sure that the mainspring is sufficiently wound and the watch is working 2 If your watch has screw lock type buttons unlock them Refer to How to use the sc...

Page 10: ...dition below0 always keep at least one sixth of the watch power shown by the power reserve indicator 5 Driving System Mainspring Self winding type with manual winding function 6 Hand movement Glide motion hands 7 Continuous operable time Approx 72 hours Approx 3 days when the normal time dis play function and stopwatch function are used If the power reserve indicator shows the power supplied by th...

Page 11: ...se contact the retailer from whom your watch was purchased or the CUSTOMER SERVICE DE PARTMENT of SEIKO WATCH CORPORATION 88 89 RASH AND ALLERGY Adjust the bracelet and band so that there will be a little clearance between the bracelet or band and your wrist to avoid accumulation of perspiration If you are constitutionally predisposed to rash the band may cause you to develop a rash or an itch dep...

Page 12: ...tance refer to Page 90 Magnetic resis tance refer to Page 92 92 93 Grand Seiko Spring Drive conforms to the Magnetic Resistance Standard of JIS Class 1 The watch has magnetic resistance to maintain performance in most cases even where it is brought close to at least 5cm spaced from equipment generating a magnetic field in normal life However the movement part is magnetized when it encounters a str...

Page 13: ...ot sufficient for the next use Return the watch to a normal temperature so that it works accurately as usual and then reset the time The watch has been adjusted so that it works accurately when it is worn on your wrist under a normal temperature range between 5 and 35 Correct this condition by moving and keeping the watch away from the magnetic source If this action does not correct the condition ...

Reviews: