6-2
6.1.2 Mounting Platen Block
Secure the platen block in the 2 locations shown below (a, b). Holes A and B are used for positioning the
outer case. Perform positioning of the outer case using A and B.
Figure 6-2 How to Secure the Platen Block
Recommended Screws
The recommended mounting screws are as follows:
Screw
:
M2.0 cross-recessed pan head machine screw
The nominal size of the screw should be the wall thickness of the outer case plus 2 mm. To secure the
platen block to the wall of a thickness of 2 mm, screws of the nominal size of 4 mm should be used.
Platen Block
Screw (2 pieces)