3-24
3.6.9 Thermistor Resistance
The resistance of the thermistor at the operating temperature T
X
(
C) is determined using the following
equation (10).
Equation (10):
{
(
)
}
298
1
-
x
T
+
273
1
×
B
EXP
×
25
R
=
X
R
R
X
:
Resistance at operating temperature Tx (
C)
R
25
: 15
k
Ω
5% (25
C)
B:
3450
k
3%
T
X
:
Operating temperature (
C)
EXP (A): The Ath power of natural logarithm e (2.71828)
[Rating]
Operating temperature range: -40
C to +125
C
Figure 3-11 Thermistor Resistance vs. Temperature
RESISTANCE
(K
Ω
)
1000
100
10
1
-40 -30
-20 -10 0 10 20 30 40 50 60 70 80 90 100
TEMPERATURE (
C)