Seiko 6R20 Instructions Manual Download Page 5

How to wind the mainspring

• This is an automatic mechanical watch with a manual winding mechanism.

• When the watch is worn on the wrist, the mainspring is wound automatically through normal wrist

movement. The watch can also be wound up by turning the crown.

• To start the watch after it stops completely, wind it up either by turning the crown or swinging it from side

to side until the seconds hand starts moving. Then, set the time and date before putting the watch on

the wrist. To wind up the watch, turn the crown clockwise slowly. The watch cannot be wound by turning

the crown counterclockwise. In this way, the watch can be wound up fully. Furthermore, turning the crown

further will not break the spring.

 * For the watch with screw down crown, please unlock the crown before operating it and be sure to lock the crown

after operating it.

• Wind the mainspring until the power reserve indicator shows a fully-wound state. Once the watch is

wound up fully, it operates for about 45 hours.

 * To check the winding state of the mainspring, refer to “Power reserve indicator” → P.14.

EN

12

1

HOW TO USE

 * If the watch is used without being wound up fully, gain or loss of time may result. To avoid this, wear the watch for

more than 10 hours a day. If the watch is used without being worn on the wrist, be sure to wind it up fully every day

at a fixed time.

 * If you use a watch that has stopped with the mainspring unwound, winding the mainspring with the crown will not

start the watch immediately. That is because the mainspring torque or force is low at the beginning of its winding

due to the characteristics of mechanical watches. The seconds hand will start to move when a certain degree of

torque is reached after the mainspring has been wound up. However, swinging the watch from side to side to

forcibly turn the balance can start the watch sooner.

EN

13

1

HOW TO USE

Power reserve indicator

• The power reserve indicator lets you know the winding state of the mainspring.

• Before removing the watch from your wrist, observe the power reserve indicator to check if the watch

has stored enough power to keep running until the next time you wear it. If necessary, wind the

mainspring. (To prevent the watch from stopping, wind the mainspring to store the excess power that

will allow the watch to run for extra time.)

 * The continuous operating time of the watch may vary depending on the conditions of your usage (such as the

number of hours you wear the watch or the extent of your movement while wearing it).

 * In a case where you wear the watch for a short period of time each day, observe the power reserve indicator to

check the level of the remaining power. If necessary, manually wind the mainspring.

EN

14

1

HOW TO USE

■ How to read the power reserve indicator

As shown in the diagram below, when the indicator is pointing near 45 or F on the scale, it is fully wound.

As the mainspring unwinds, the indicator will move toward 0 or E.

 * The accuracy of a mechanical watch is affected by the winding amount of the mainspring. If the watch is used

for a long time when the winding amount is 20 hours or less, stable accuracy may not be obtained. Therefore,

it is recommended that the winding amount be between 20 hours and full winding when you use the watch.

 * Once the mainspring is fully wound, it will slip if you wind it further, so there is no chance of the mainspring

breaking even if it is over wound.

 * The indicator may move beyond 0 or E, but this is not a malfunction.

The Power

Reserve Indicator

The winding state

of the mainspring Fully wound

Half wound

Unwound

The number of

hours the watch

can run

Approximately 45 hours

Approximately 20 hours

The watch either stops or is

running down.

 * Designs vary depending on the model. Refer to the above diagram to read the approximate continuous operating

time.

EN

15

1

HOW TO USE

Summary of Contents for 6R20

Page 1: ...TIONS MECHANICAL WATCH https www seikowatches com English 1 JA 1 EN Deutsch Fran ais Italiano Espa ol P Portugu s Please refer to the Instruction Manuals of other languages by accessing Customer Servi...

Page 2: ...e power reserve indicator 15 How to set the time date and day of the week 16 How to set the time 17 How to set the date and day of the week 19 Date adjustment at the end of the month 21 2 TO PRESERVE...

Page 3: ...faucet is high enough to degrade the water resistant performance of a water resistant watch for everyday life EN 5 1 HOW TO USE b CAUTION Please note that there is a risk of minor injury or material...

Page 4: ...ary depending on the model 1 6 7 2 4 5 3 EN 9 1 HOW TO USE 6R27 1 Minute hand 2 Hour hand 3 Power reserve indicator 4 Seconds hand 5 Date hand 6 Crown Normal position not locked Wind up the watch hand...

Page 5: ...alance can start the watch sooner EN 13 1 HOW TO USE Power reserve indicator The power reserve indicator lets you know the winding state of the mainspring Before removing the watch from your wrist obs...

Page 6: ...til they indicate the current time Make sure that AM PM is correctly set EN 17 1 HOW TO USE 4 Push the crown back in to the normal position in accordance with a time signal The seconds hand immediatel...

Page 7: ...The watch requires good daily care Do not wash the watch when its crown is in the extended position Wipe away moisture sweat or dirt with a soft cloth After soaking the watch in seawater be sure to w...

Page 8: ...atch before using Please look at P 23 Indication on the case back Water resistant performance Conditions of Use No indication Non water resistance Avoid drops of water or sweat WATER RESISTANT Water r...

Page 9: ...ee bands while bathing swimming and when working with water even if the watch itself is water resistant enforced for daily use 10 BAR 20 BAR water resistant Polyurethane band A polyurethane band is su...

Page 10: ...the pin into the adjustment hole at an appropriate length Push the buckle and fasten the clasp Buckle Pin Adjustment hole EN 33 2 TO PRESERVE THE QUALITY OF YOUR WATCH C C Type How to wear or take off...

Page 11: ...ESERVE THE QUALITY OF YOUR WATCH How to wear the band Opening and closing the clasp Push button Buckle 1 Lightly press the push buttons to open the clasp Note that pressing the push buttons too firmly...

Page 12: ...ime also request replacement of the gasket and the spring bar When your watch is inspected and adjusted by disassembly and cleaning overhauled the movement of your watch may be replaced EN 41 2 TO PRE...

Page 13: ...RESERVE THE QUALITY OF YOUR WATCH Troubles Possible causes Solutions The date changes at 12 o clock noon AM PM is not properly set Advance the hands by 12 hours Blur in the display persists A small am...

Reviews: