background image

7

PARTS CATALOGUE

Cal. 5J22A

Remarks:

8

Date dial

Part code

0878 936

3 o’clock

Color of figure

Color of

background

White

Black

Position of crown

4 o’clock (outer)

Position of

calendar frame

0878 937

3 o’clock

Black

White

4 o’clock (outer)

0878 940

3 o’clock

White

Black

4 o’clock (inner)

0878 941

3 o’clock

Black

White

4 o’clock (inner)

The type of date dial is determined based on the design of cases.  (The table above does not cover all
the date dial available.)
Check the case number and refer to “SEIKO Casing Parts Catalogue” to choose a corresponding date
dial.

56

Winding stem   0351 557

The type of winding stem is determined based on the design of cases.

Check the case number and refer to “SEIKO Casing Parts Catalogue” to choose a corresponding
winding stem.

TECHNICAL GUIDE

Cal. 5J22A

The explanation here is only for the particular points of Cal. 5J22A.

For the repairing, checking and measuring procedures, refer to the “TECHNICAL GUIDE, GENERAL
INSTRUCTIONS”.

I.

STRUCTURE OF THE CIRCUIT BLOCK

Automatic generating

input terminal

Input terminal (+)

Input terminal (–)

Second coil output terminal

Crystal unit

C-MOS-IC

Hour and minute coil
detection terminal

Hour and minute coil output terminal

Summary of Contents for 5J22A

Page 1: ...tomatic power save function Manual power save function Time relay function Driving system Step motor Load compensated driving pulse type 2 pieces Loss gain Monthly rate at normal temperature range les...

Page 2: ...you decide no to use the watch for a long time By pulling out the crown to the first click and pushing it in to the normal position within one second the power save function is activated manually Note...

Page 3: ...t screw 1 pc 1 Hour minute and second hands 2 Dial 3 0012 354 Date dial guard screw 4 0353 558 Hour wheel guard spring 5 0808 557 Date dial guard 8 Date dial 7 0962 558 Second intermediate wheel for c...

Page 4: ...clamp screw 17 4225 522 Rechargeable battery clamp 18 4216 524 Insulator for rechargeable battery 19 3023 24X Rechargeable battery unit 20 0012 354 Circuit block cover A screw 21 4457 771 Circuit blo...

Page 5: ...nerating coil block 35 0317 557 Intermediate second wheel 36 0241 557 Fourth wheel and pinion 37 0231 557 Third wheel and pinion 38 4146 521 Second rotor 39 4146 521 Hour and minute rotor 40 0281 552...

Page 6: ...0388 557 Setting lever spring 50 0383 557 Setting lever 51 0384 557 Yoke 52 0391 557 Train wheel setting lever 53 4239 524 Generating stator 54 4239 523 Second stator 55 4239 522 Hour and minute stato...

Page 7: ...o SEIKO Casing Parts Catalogue to choose a corresponding date dial 56 Winding stem 0351 557 The type of winding stem is determined based on the design of cases Check the case number and refer to SEIKO...

Page 8: ...e crown to the second click and turn it counterclockwise 2 Check if the date numeral moves in the calendar frame When it starts to move turn the crown slowly and stop turning it when the numeral stops...

Page 9: ...heel in the direction as shown in the illustration at right Make sure that its longer pivot faces the movement side How to install 1 Apply the spring portion of the date driving wheel spring to the lo...

Page 10: ...to the A portion gap in the illustration and pry up the rechargeable battery unit to remove it How to install Set the minus lead terminal to the guide post B in the illustration push C portion down ve...

Page 11: ...ng rotor Note Be sure to observe the position type of oil and quantity of the lubrication specified in the illustration 28 Circuit block The portions indicated by the arrows in the illustration have e...

Page 12: ...nd wheel They can be discriminated by the thickness of the pinions The third wheel and pinion has the thicker pinion 41 Intermediate minute wheel Case back side Main plate side Note Do not set the int...

Page 13: ...d are made tight for the guide tubes to which they are set After setting the spacer for center wheel and pinion press down those portions so that it is well seated in position A portion B portion 48 S...

Page 14: ...saving switch lead pin Do not remove the power saving switch lead pin except when necessary When installing the power saving switch lead pin press it in securely to the circuit block spacer Power savi...

Page 15: ...for detecting generation Checking for leakage between coil for driving hands and coil for detecting generation If the hour and minute hands do not move properly when the time relay function is activa...

Page 16: ...and a stable measurement can be obtained read the measurement If the measurement value remains high or unstable repeat step 3 above 1 Disassemble unnecessary parts to make the movement ready for the...

Page 17: ...be switched from the quick start to the normal hand movement mode 3 Checking that a stable measurement is obtained read the current consumption Notes The current consumption measurement for the circui...

Page 18: ...onserve the stored energy and the time relay function to start the hands moving to indicate the current time as the power save function is canceled For your information 1 Number of swings and power re...

Page 19: ...al 5J22A which you will find helpful in working on the watch 1 The power save function is activated after the watch is left untouched for approximately 72 hours 2 The manual power save function is act...

Page 20: ...Page 15 The current consump tion for the whole of the movement exceeds the standard value 1 After connecting the tester move the oscillating weight more quickly for a longer period of time and then ma...

Page 21: ...ace the part if leakage is detected 1 There is electric leakage inside the hour and minute coil block After the time relay function is activated the hands do not make the quick movement smoothly or th...

Reviews: