background image

18

TECHNICAL GUIDE

Cal. 5J22A

2.

Close the case back tentatively, and swing the watch
from side to side 200 times at a rate of 2 to 3 swings a
second, making an arc of approximately 20 cm.

3.

Within 3 minutes after swinging the watch, measure
the voltage of the rechargeable battery in the same
manner as in step “1” above.

4.

Refer to the table below, and decide whether the automatic generating system is normal or defective.

[ Initial voltage and guidelines of normal/defective decision ]

Initial voltage

Guidelines of normal/defective decision

After charging, the voltage of rechargeable battery has increased 0.1 V or
more from the initial voltage.

0.45 V ~ 1.0 V

After charging, the voltage of rechargeable battery has increased 0.05 V or
more from the initial voltage.

* The guidelines specified in the above table apply only when the initial voltage is within the range

between 0.45 V and 1.2 V.

* The amount of electricity generated by swinging the watch varies depending on the manner in which

you swing it, such the rate of swinging and the size of the swinging arc.  Please note, therefore, that
checking through the procedure above provides only the guideline of normal/defective decision.

Checking the manual power save and time relay functions

Cal. 5J22A is equipped with the automatic and the manual power save functions to conserve the stored
energy and the time relay function to start the hands moving to indicate the current time as the power
save function is canceled.

[ For your information ]

1.

Number of swings and power reserve

·

When the power reserve in the rechargeable battery is depleted and the watch stops completely,
swinging it approximately 500 times at a rate of 2 to 3 times a second will start the second hand
moving at normal one-second intervals instead of two-second intervals.  If the second hand still
moves at two-second intervals after 500 swings, swing the watch further until it moves at one-
second intervals.

·

While the second hand is moving at one-second intervals, approximately 200 swings will reserve
up to one day of power.

2.

The number of days over which the watch is worn and power reserve

·

Wearing the watch continuously for 12 hours will accumulate approximately one and a half
additional days of power reserve.

If you wear the watch every day for 12 hours over a period of a week, approximately 10 days of power
reserve will be secured in the rechargeable battery.  While the power saving function is in operation
and the hands are stopped, this amount of power reserve will keep the watch operating  for
approximately 2 months.

Note: The checking procedure below can be performed only while the watch is operating.  If the watch

stops completely, swing the watch until the second hand starts moving at one-second intervals.
Swing it further more than 200 times, and then, proceed to the checking procedure.

1.01 V ~ 1.2 V

Summary of Contents for 5J22A

Page 1: ...tomatic power save function Manual power save function Time relay function Driving system Step motor Load compensated driving pulse type 2 pieces Loss gain Monthly rate at normal temperature range les...

Page 2: ...you decide no to use the watch for a long time By pulling out the crown to the first click and pushing it in to the normal position within one second the power save function is activated manually Note...

Page 3: ...t screw 1 pc 1 Hour minute and second hands 2 Dial 3 0012 354 Date dial guard screw 4 0353 558 Hour wheel guard spring 5 0808 557 Date dial guard 8 Date dial 7 0962 558 Second intermediate wheel for c...

Page 4: ...clamp screw 17 4225 522 Rechargeable battery clamp 18 4216 524 Insulator for rechargeable battery 19 3023 24X Rechargeable battery unit 20 0012 354 Circuit block cover A screw 21 4457 771 Circuit blo...

Page 5: ...nerating coil block 35 0317 557 Intermediate second wheel 36 0241 557 Fourth wheel and pinion 37 0231 557 Third wheel and pinion 38 4146 521 Second rotor 39 4146 521 Hour and minute rotor 40 0281 552...

Page 6: ...0388 557 Setting lever spring 50 0383 557 Setting lever 51 0384 557 Yoke 52 0391 557 Train wheel setting lever 53 4239 524 Generating stator 54 4239 523 Second stator 55 4239 522 Hour and minute stato...

Page 7: ...o SEIKO Casing Parts Catalogue to choose a corresponding date dial 56 Winding stem 0351 557 The type of winding stem is determined based on the design of cases Check the case number and refer to SEIKO...

Page 8: ...e crown to the second click and turn it counterclockwise 2 Check if the date numeral moves in the calendar frame When it starts to move turn the crown slowly and stop turning it when the numeral stops...

Page 9: ...heel in the direction as shown in the illustration at right Make sure that its longer pivot faces the movement side How to install 1 Apply the spring portion of the date driving wheel spring to the lo...

Page 10: ...to the A portion gap in the illustration and pry up the rechargeable battery unit to remove it How to install Set the minus lead terminal to the guide post B in the illustration push C portion down ve...

Page 11: ...ng rotor Note Be sure to observe the position type of oil and quantity of the lubrication specified in the illustration 28 Circuit block The portions indicated by the arrows in the illustration have e...

Page 12: ...nd wheel They can be discriminated by the thickness of the pinions The third wheel and pinion has the thicker pinion 41 Intermediate minute wheel Case back side Main plate side Note Do not set the int...

Page 13: ...d are made tight for the guide tubes to which they are set After setting the spacer for center wheel and pinion press down those portions so that it is well seated in position A portion B portion 48 S...

Page 14: ...saving switch lead pin Do not remove the power saving switch lead pin except when necessary When installing the power saving switch lead pin press it in securely to the circuit block spacer Power savi...

Page 15: ...for detecting generation Checking for leakage between coil for driving hands and coil for detecting generation If the hour and minute hands do not move properly when the time relay function is activa...

Page 16: ...and a stable measurement can be obtained read the measurement If the measurement value remains high or unstable repeat step 3 above 1 Disassemble unnecessary parts to make the movement ready for the...

Page 17: ...be switched from the quick start to the normal hand movement mode 3 Checking that a stable measurement is obtained read the current consumption Notes The current consumption measurement for the circui...

Page 18: ...onserve the stored energy and the time relay function to start the hands moving to indicate the current time as the power save function is canceled For your information 1 Number of swings and power re...

Page 19: ...al 5J22A which you will find helpful in working on the watch 1 The power save function is activated after the watch is left untouched for approximately 72 hours 2 The manual power save function is act...

Page 20: ...Page 15 The current consump tion for the whole of the movement exceeds the standard value 1 After connecting the tester move the oscillating weight more quickly for a longer period of time and then ma...

Page 21: ...ace the part if leakage is detected 1 There is electric leakage inside the hour and minute coil block After the time relay function is activated the hands do not make the quick movement smoothly or th...