- 26 -
10. Cycle Start / Stop in the various operating conditions
10.1 Auto Start
- Where fastening number count is not necessary
It starts to count the number of fastening automatically just after cycle end with "0"
display of counter, and repeats without any cycle start and stop signal for counting.
"Auto Start" can be used for monitoring fastening OK / NG condition without counting
of fastening numbers.
10.2 Start ( Continuous ON )
Scout starts counting the fastening number from the ON signal edge and keep
counting till signal OFF. If the number reaches to the target before signal OFF, it
makes the Cycle complete OK and provide Cycle end output signal.
Also it verify the Cycle complete NG, If the ON status turned OFF which means that
the fastening work is finished, because the work piece left the working area.
The display is reset to the target number when the Cycle Start signal is turned ON
again.
work piece
working
area
switch or sensor
ON status
OFF
ON edge