- 12 -
6.7
Parameters
P #
Name
Specification
Default
P01-
P08
Program #
Save total number of screws on P1-8.
1
P09-
P16
Minimum tightening
time
Minimum screw tightening time
Input : 0.000 - 9.999 sec ( "0" : No use )
0
P17-
P24
Maximum tightening
time
Maximum screw tightening time
Input : 0.000 - 9.999 sec ( "0" : No use )
0
P25
Type of cycle start
and stop
Select one of 4 types of Cycle Start signal
input
0 : Auto
1 : Start (continuous ON)
2 : Start (pulse ON) + Stop (timer on P27)
3 : Start (pulse ON) + Stop (pulse ON)
0
P26
Input signal type
Select one of 2 signal type
0 : Active High
( 0 --> 1 )
1 : Active Low
( 1 --> 0 )
※
When Active Low is selected, the only
one(1) screwdriver ("A") can be connected.
0
P27
Timer setting for
Cycle start/stop type
2 of P25
Input screw tightening time limit after Cycle
start signal
Input : 0.0 - 9.9 sec ( "0" : No use )
0
P28
Minimum time to
judgement
Set the minimum time to judgement of
OK/NG
Input : 0 - 99 ( x 0.1s )
( "0" : No use )
0
P29
Com port select
Select one of two com ports.
0 : USB
1 : RS-232C
0
P30
Hybrid HDC connect
Select one of two condition
0 : Not Connected (not use)
1 : Connected (used)
0