SERVICE MANUAL
iHunter Series
- 117 -
(7) Press and hold down the
RESTART
Key until the machine show below message on the
LCD DISPLAY.
(8) Press the
MODE
Key until the machine show below message on the LCD DISPLAY.
The item No. 3 is selected.
(14) Press the
MODE
key and select the item 3, 3. CF PART.
(15) Press the
key and enter the item 3, 3. CF PART.
(16) Press the
CURRENCY
key and display shows as below.
(17) Press the
MODE
key and select the item 1. IR OFFSET SETTING.
(18) Press the
key and enter the item 1. IR OFFSET SETTING.
CF -> UV, MG
CURRENCY -> IR
I R S E T T I N G S E L E C T
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
E X I T
> > 1 . I R O F F S E T S E T T I N G
2 . I R G A I N S E T T I N G
3 . I R V I E W I M A G E
S E L E C T S E T T I N G S E N S O R G R O U P
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
1 . E X I T ( R E S T A R T K E Y )
2 . M A I N P A R T
> > 3 . C F P A R T
4 . C I S P A R T
5 . Q . C . R E P O R T
S E L E C T S E T T I N G S E N S O R G R O U P
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
> > 1 . E X I T ( R E S T A R T K E Y )
2 . M A I N P A R T
3 . C F P A R T
4 . C I S P A R T
5 . Q . C . R E P O R T
Summary of Contents for iHunter 2.0 CIS/FIT
Page 1: ...SERVICE MANUAL iHUNTER Series REV 1 0 ...
Page 39: ...SERVICE MANUAL iHunter Series 39 5 6 TROUBLE SHOOTING Please ask to factory or agent company ...
Page 64: ...SERVICE MANUAL iHunter Series 64 13 Remove the IR REAR SENSOR board assembly ...
Page 93: ...SERVICE MANUAL iHunter Series 93 Click the Continue Anyway button ...