background image

   MAGIQTOUCH BMS INDUSTRIAL CONTROLLER - MANUAL  

|  

3

 

SAFETY

This document provides technical guidance on the installation and operation of the 

MagIQtouch BMS Industrial Controller MS1.

EMPLOYER AND EMPLOYEE RESPONSIBILITIES

Please read this manual carefully. Your failure to do so could result in injury to you or 

damage to the cooler and property.
The installation and maintenance of coolers at height has the potential to create 

Occupational Health and Safety issues for those involved. Installers are advised to 

ensure they are familiar with Local Acts, Regulations and Standards, which may offer 

practical guidance on health and safety issues. Compliance with these regulations will 

require appropriate work practices, equipment, training and qualifications of workers.

INSTALLER AND MAINTENANCE CONTRACTORS – RISK ASSESSMENT

Seeley International provides the following information as a guide to contractors and 

employees to assist in minimising risk whilst working at height. 
A risk assessment of all hazardous tasks is required under legislation. A risk assessment 

is an essential element that should be conducted before the commencement of work, to 

identify and eliminate the risk of falls or to minimise these risks by implementing control 

measures. There is no need for this to be a complicated process, it just is a matter 

of looking at the job to be done and considering what action(s) are necessary so the 

person doing the job does not injure themselves.
This should be considered in terms of:
What are the chances of an incident happening?
What could the possible consequence be?
What can you do to reduce, or better still, completely get rid of the risk?

WARNING! 

The MagIQtouch BMS Controller requires an approved Safety Extra Low Voltage (SELV) 

12Vdc power supply to be connected to the power supply input of the MagIQtouch BMS 

controller. The outputs from the controller require this approved SELV power supply in 

order to maintain the SELV circuit. Except for the RJ 6 way connection to the cooler, 

other inputs and outputs should only be connected to the SELV circuit of the building 

management system. Interconnection wiring between the MagIQtouch BMS controller 

and the building management system shall be separated by reinforced insulation to any 

live parts. Installation and location of the BMS controller shall be sufficiently separated 

from live parts to comply with reinforced insulation.
This MagIQtouch BMS Industrial Controller is to be installed indoors only, installation 

shall only be performed by suitably trained and qualified personnel, in accordance with 

local and national wiring rules. 
This appliance is not intended for use by persons (including children) with reduced 

physical, sensory or mental capabilities, or lack of experience and knowledge, unless 

they have been given supervision or instruction concerning use of the appliance by a 

person responsible for their safety. Children should be supervised to ensure that they 

do not play with the appliance. If any cables are damaged, they shall be replaced by the 

manufacturer or its service agent or similarly qualified person in order to avoid a hazard. 

Stranded conductors shall not be consolidated by lead-tin soldering where they are 

subject to contact pressure, i.e. on terminal block.

Summary of Contents for MAGICTOUCH MS1

Page 1: ...UT SET FAN SPEED INPUT PWR ERROR CODE SIG GND SIG GND 12VDC 0VDC POWER INPUT BMS INDUSTRIAL CONTROLLER M1 BMS INDUSTRIAL CONTROLLER MS1 ILL2470 A INSTALLATION OPERATION MANUAL MagIQtouch BMS Industrial Controller MS1 Coolers Only Original English Instructions English Industrial Controller MS1 ...

Page 2: ...i ...

Page 3: ...ount 7 ELECTRICAL INSTALLATION 8 Typical Installation Options 8 Master Mode Single Cooler 8 Master Mode Multi Coolers 8 Slave Mode Single Cooler Option 1 9 Slave Mode Single Cooler Option 2 9 Slave Mode Multiple Coolers Option 1 10 Slave Mode Multiple Coolers Option 2 10 Master Or Slave Mode 11 Master Mode 11 Slave Mode 11 Activating Master Or Slave Mode 11 Connecting Cooler or Wall Control to BMS...

Page 4: ...l 3 2 Wall Brackets 4 2 Wall Plug Yellow 5mm 5 2 Screw PAN PHIL 6ABX1 ZNP 6 ILL2471 A 1 3m Communications Cable ILL2109 A SIG GND ERROR STATUS OUTPUT COOL INPUT ACTUAL FAN SPEED OUTPUT SIG GND SIG GND SYSTEM ON INPUT SET FAN SPEED INPUT PWR ERROR CODE SIG GND SIG GND 12VDC 0VDC POWER INPUT BMS INDUSTRIAL CONTROLLER M1 BMS INDUSTRIAL CONTROLLER MS1 ILL2470 A INSTALLATION OPERATION MANUAL MagIQtouch...

Page 5: ...nt happening What could the possible consequence be What can you do to reduce or better still completely get rid of the risk WARNING The MagIQtouch BMS Controller requires an approved Safety Extra Low Voltage SELV 12Vdc power supply to be connected to the power supply input of the MagIQtouch BMS controller The outputs from the controller require this approved SELV power supply in order to maintain...

Page 6: ...nnected from the power source when installing the MagIQtouch BMS Industrial Controller select and prepare an appropriate mounting site with the following features Space for mounting on either DIN rail or directly to the wall Clearance for inserting digital analogue inputs outputs Within 100m of cooler Dedicated 12Vdc power input for Actual fan speed and logic Error Status signal Note Do not use po...

Page 7: ...cturer s warranty 100m 328 MAX Seeley International cooler SIG GND ERROR STATUS OUTPUT COOL INPUT ACTUAL FAN SPEED OUTPUT SIG GND SIG GND SYSTEM ON INPUT SET FAN SPEED INPUT PWR ERROR CODE SIG GND SIG GND 12VDC 0VDC POWER INPUT BMS INDUSTRIAL CONTROLLER M1 BMS INDUSTRIAL CONTROLLER MS1 ILL2472 A MASTER MODE Maximum cable length SLAVE MODE Maximum cable length Seeley International cooler SIG GND ER...

Page 8: ...ouch Industrial Wall Controller cable ferrite 864402 40m 131 MagIQtouch Industrial Wall Controller cable ferrite 834238 60m 197 MagIQtouch Industrial Wall Controller cable No ferrite 834474 500m 1640 Roll of 6 core ribbon cable with no terminations or plugs Plug Type 6 pin Farnell 781 289 wired as below 670423 Hinged Bracket Ferrite BLUE YELLOW GREEN RED BLACK WHITE ILL2123 A COMMUNICATION CABLE c...

Page 9: ...MS MS1 is suitable for internal installations only Within the MagIQtouch BMS Industrial Controller kit are 2 x wall brackets push fit them into the each side of the enclosure base Mark and drill suitable holes in wall and insert wall plugs provided Align and screw the MagIQtouch BMS Industrial Controller on to the wall ILL2103 A ILL2104 A SIG GND ERROR STATUS OUTPUT COOL INPUT ACTUAL FAN SPEED OUT...

Page 10: ...S1 Master per 1 x cooler MASTER MODE MULTI COOLERS NOTE 1 x BMS MS1 Master per 1 x cooler EVAP COOLER 3 EVAP COOLER 2 EVAP COOLER 1 CUSTOMER BMS 100m SIG GND ERROR STATUS OUTPUT COOL INPUT ACTUAL FAN SPEED OUTPUT SIG GND SIG GND SYSTEM ON INPUT SET FAN SPEED INPUT PWR ERROR CODE SIG GND SIG GND 12VDC 0VDC POWER INPUT BMS INDUSTRIAL CONTROLLER M1 BMS INDUSTRIAL CONTROLLER MS1 SIG GND ERROR STATUS O...

Page 11: ...ND SIG GND SYSTEM ON INPUT SET FAN SPEED INPUT PWR ERROR CODE SIG GND SIG GND 12VDC 0VDC POWER INPUT BMS INDUSTRIAL CONTROLLER M1 BMS INDUSTRIAL CONTROLLER MS1 ILL2476 B ILL2476 B EVAP COOLER 1 CUSTOMER BMS 20m BMS MS1 SIG GND ERROR STATUS OUTPUT COOL INPUT ACTUAL FAN SPEED OUTPUT SIG GND SIG GND SYSTEM ON INPUT SET FAN SPEED INPUT PWR ERROR CODE SIG GND SIG GND 12VDC 0VDC POWER INPUT BMS INDUSTRI...

Page 12: ...10 ELECTRICAL INSTALLATION cont SLAVE MODE Multiple Coolers Option 1 With link modules SLAVE MODE Multiple Coolers Option 2 With Dual RJ socket on Cooler electronics ILL2478 B ILL2479 C ...

Page 13: ...ration Slave Mode The BMS MS1 controller is a Slave to the MagIQtouch wall controller When the BMS MS1 ON OFF signal is ON the BMS MS1 controller takes control of the MagIQtouch wall control remotely During remote access the MagIQtouch wall control will display BMS CONTROL and will not be operational Activating Master or Slave Mode Remove the front cover of the BMS MS1 controller and set the dip s...

Page 14: ...12 ELECTRICAL INSTALLATION cont CONNECTING COOLER OR WALL CONTROL TO BMS MS1 ILL2481 A ILL2481 A ...

Page 15: ...e Label Function Low High Input Type On Off SYSTEM ON INPUT Master mode only Turn Cooler On or Off Cooler Off Cooler On Digital 10Vdc Slave mode only Switch operation between Wall control and BMS MagIQtouch Control BMS Control Digital 10Vdc Operation Mode COOL INPUT Cool or Vent Fan Only Cool Mode Digital 10Vdc Fan Speed SET FAN SPEED INPUT Set speed from 1 10 N A N A Analogue 0 10Vdc Logical Leve...

Page 16: ...0 0 0 1 2 8 2 2 2 3 6 2 8 3 4 4 3 6 4 5 2 4 4 5 6 0 5 2 6 6 7 6 0 7 7 5 6 8 8 8 2 7 5 9 9 0 8 3 10 10 0 Optional 12Vdc power input POWER IN 12VDC Power input only required if ACT FAN SPEED and ERROR STATUS signals are required from the module If Power input is not connected ERROR STATUS and ACT FAN SPEED will not work Min Typ Max Unit Voltage DC 11 5 12 12 5 V ...

Page 17: ...ROR ERROR PULL UP RESISTOR BMS DC POWER RAIL V BMS 0V BMS MS1 MODULE Monitor Voltage V No Error V Error ERROR ERROR BMS DC POWER RAIL V BMS 0V BMS MS1 MODULE Contact open No Error Contact closed Error Normally Open contacts1 RELAY COIL ILL2484 B POWER IN 12V ERROR ERROR R18 RXE005 D3 ISMA4753 POWER IN 0V R22 470R R15 4K7 3 1 2 C E B Q1 BC640 ILL2483 B OUTPUT SIGNALS ERROR STATUS ILL2483 B The diag...

Page 18: ...ng on the precision of the POWER IN 12V supply ELECTRICAL INSTALLATION cont Actual Fan Speed VOUT min VOUT typ VOUT max 0 0 0 0 8 1 0 1 1 0 1 3 1 6 2 1 7 2 2 2 5 3 2 7 3 2 3 5 4 3 7 4 2 4 5 5 4 7 5 2 5 5 6 5 7 6 2 6 5 7 6 8 7 2 7 5 8 7 8 8 2 8 6 9 8 8 9 3 9 6 10 9 8 10 3 12 0 ...

Page 19: ...g on the front panel The type of error will be indicated by the sequence of flashes highlighted on ERROR CODE LED Errors can be cleared by applying a low level and then high level on the SYSTEM ON INPUT Error codes can be cleared using the RESET button on the front of the controller OFF BMS Module Off no power received from Cooler on RJ port ON BMS is operational Communication to Cooler and Wall C...

Page 20: ...18 CONNECTION DIAGRAM ILL2512 B ...

Page 21: ...tch position Cycle power to Cooler Cable not connected correctly Refit cable Cycle power to cooler Cable damaged or broken Replace cable Cycle power to cooler The PWR LED is flashing multiple flashes sequence The cooler has a fault Refer to cooler manual to solve the fault on the cooler Cycle power to cooler The PWR LED is illuminated but the Cooler is not starting The ON input is not set to High ...

Page 22: ......

Page 23: ......

Page 24: ... the specifications of the model selected MANUFACTURED BY Seeley International Pty Ltd 112 O Sullivan Beach Road Lonsdale SA 5160 Australia for Australia USA Europe and South Africa IMPORTED BY Seeley International Americas Ltd 1002 S 56th Avenue Suite 101 Phoenix Arizona 85043 USA Seeley International Europe Limited Unit 11 Byron Business Centre Duke Street Hucknall Nottingham NG15 7HP United Kin...

Reviews: