BREEZAIR EXQ/EXS/EXVQ EVAPORATIVE COOLER OWNER’S MANUAL
|
5
MAGIQCOOL CONTROLLER
OPERATION
If ‘02’ is displayed
(1)......Check that the water supply tap to the
cooler is turned on.
(2)......Check that your local water authority
haven’t temporarily disconnected the water in
your area.
If ‘04’ is displayed
(1)......If your cooler is fitted with a drain valve,
check that the drain is not blocked.
If these do not fix the problem then contact
your dealer or the service number near the
back of this manual. You will need to quote the
flashing number that you wrote down.
Drain Mode (Cooler switched OFF)
Pressing the and buttons at
the same time for 2 seconds will open the drain
valve and empty the water in the tank. The wall
control will display “
dr
” on the screen. Draining
the water will leave the tank clean and dry until
it is next used.
WATER MANAGEMENT
Your evaporative cooler will be fitted with either
a WaterMiser
®
system, or a continuous bleed
system. Check with your dealer to determine
which system has been installed.
WATERMISER
®
Breezair
®
evaporative coolers are fitted with
the WaterMiser
®
feature which automatically
monitors the quality of the water in the cooler.
The WaterMiser
®
drains the existing water in
the cooler to allow it to be replaced with fresh
water, only when it is needed. Therefore,
you may notice your cooler draining water
occasionally. How often the WaterMiser
®
performs this operation depends upon the
quality of the water supply and the rate of
evaporation. In areas of poor water quality, the
WaterMiser
®
will operate more often as it tries
to maintain the optimum water quality in the
cooler. This maximises the cooling effect and
life of the cooling pads.
The WaterMiser
®
allows you to specify either
high or low salinity settings. The low salinity
setting is used in specific circumstances only.
We recommend talking with your dealer before
adjusting this setting.
The high salinity setting is designed to operate
the cooler at a maximum safe salinity level to
maintain a normal working life. It also results in
a minimum usage of water.
Note!
High salinity outlet water can be used on
saline tolerant gardens, but should not be used
on salt sensitive grasses or plants.
The factory default WaterMiser
®
setting is
HI. For areas operating with bore water,
WaterMiser
®
should be switched to off.
This will disable the salinity measuring circuit
and simply drain water from the tank every
65 minutes of operation.