background image

    BREEZAIR EXQ/EXS/EXVQ EVAPORATIVE COOLER OWNER’S MANUAL  

|  

1

 

Hello and congratulations on 

purchasing a Seeley evaporative 

cooler

Refer to the Owner’s Manual supplied with the 

controller for operating instructions.

ILL1582-C

Your MagIQtouch Controller contains a settings 

menu, which gives you access to information 

about your evaporative cooler and to extra 

functions including: 

About Appliance

Access information about the appliances 

installed in your system.

Min/Max Set Temperature

You can change the minimum and maximum 

temperature displayed on your slider, 

depending on what temperature range you 

prefer your system to work within.

Night Quiet Mode

Restrict fan speed over the night time period 

for a quiet night’s sleep.

Manual Drain

This will turn the cooler off and drain the tank.

Pad Flush

This will turn the cooler off and run the pumps 

for a specified time. Use this feature to flush 

the cooler pads.

Drain and Dry

This option allows you to nominate a time each 

day when the cooler will drain the tank and run 

the fan for 1 hour.

Autoclean

Select the preferred cleaning interval (50 / 100 

/ 200 hrs). At 8.00am after the selected running 

hours has been reached, the cooler will drain 

the tank, fill with fresh water and operate the 

pump for 5 minutes. When complete, drains 

the tank and returns to previous operation 

mode. 

External Sensor

EXS models are fitted with an external air 

sensor. When switched on, it displays a live 

external ambient temperature reading on the 

wall controller. A desired external temperature 

set point can be programmed to turn off the 

pump conserving water usage and reducing 

humidity while the cooler is running. In addition 

where climate conditions are close to freezing, 

an external temperature set point can be 

programmed to auto drain the tank and prevent 

freezing conditions damaging the tank.

Note!

 There are some settings, which are 

locked and are only for installers or service 

technicians. 

At Seeley International we manufacture 

Breezair

®

 evaporative coolers from the highest 

quality materials, and we have designed the 

product to provide many years of economical, 

trouble-free cooling.

OPERATING YOUR COOLER

To provide efficient cooling or ventilation the 

building must have sufficient exhaust openings 

to the outside of the building. To assist air flow, 

open windows and doors that are farthest from 

the outlet vent in each room. In these rooms, 

provide an exhaust opening about 2 times the 

vent size of the room.
Where the design of the building prevents 

adequate exhaust, consideration should 

be given to the provision of mechanical 

extractions, such as an exhaust fan.
There are three main ways that an evaporative 

cooler can operate to provide cooling comfort. 
•  The cooler can be set at a constant fan 

speed, without reference to the current 

temperature. 

•  The cooler can be given a temperature 

target, in which case it will vary the fan 

speed in order to get as close to the 

target as possible. (

Note!

 Humid weather 

conditions may limit what temperatures can 

be achieved.)

•  The cooler can be set to a fan only mode, 

providing air circulation only.

MAGIQTOUCH CONTROLLER 

OPERATION

Summary of Contents for Breezair EXQ

Page 1: ...OWNER S MANUAL EXQ EXS EXVQ Evaporative Coolers English Original English Instructions ILL1672 A S E R I E S I C N ...

Page 2: ...ance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard New hose sets supplied with the appliance are to be used and old hose sets should not be re used WARNING TO REDUCE THE RISK OF ...

Page 3: ...er s Manual As with any product that has moving parts or is subject to wear and tear it is VERY IMPORTANT that you maintain the product and have it regularly serviced It is a condition of warranty cover for your product that you comply with all of the maintenance and service requirements set out in the Owner s Manual Compliance with these requirements will prolong the life of your product IMPORTAN...

Page 4: ...urning the Cooler On 2 Preparing to Start 2 Manual Mode 2 Auto Mode 3 Delayed Start or Stop 3 Programming In Manual Mode 3 Programming In Auto Mode 4 Service Mode 4 Drain Mode Cooler switched OFF 5 WATER MANAGEMENT 5 WATERMISER 5 Drain Valve 6 Bleed System 6 POWER OUTAGES 6 HEALTH REGULATIONS 6 MAINTENANCE 6 SCHEDULED MAINTENANCE 6 ACCESS FOR SERVICING AND MAINTENANCE 7 SEASONAL MAINTENANCE 7 Pre ...

Page 5: ...ure reading on the wall controller A desired external temperature set point can be programmed to turn off the pump conserving water usage and reducing humidity while the cooler is running In addition where climate conditions are close to freezing an external temperature set point can be programmed to auto drain the tank and prevent freezing conditions damaging the tank Note There are some settings...

Page 6: ...l switched ON press the button until MAN is shown on the display ILL1122 A ILL2121 A MAGIQCOOL CONTROLLER OPERATION MAGIQCOOL CONTROLLER SETTINGS MagIQcool Wall Controllers can operate in manual or automatic mode Manual mode Manual mode will allow you to change settings for operating the cooler such as altering fan speeds pump control and manual drain control Auto mode Auto mode will allow thermos...

Page 7: ...quire more cool air or the button if you require less Don t alter the setting however until the room temperature has stabilised Delayed Start or Stop The cooler can be programmed to start at a specific time or stop at a specific time The delayed start time can only be programmed when the cooler is OFF To program the cooler to start in a certain amount of hours use the following sequence Programmin...

Page 8: ...s again Service Mode When a fault has been recognised by the wall control the word Service flashes on the screen When Service is displayed it may be necessary for you to phone the service number located near the back of this manual However before doing so turn the wall control OFF You will notice a number flashing at the bottom of the screen This number indicates the reason for requiring service P...

Page 9: ...nitors the quality of the water in the cooler The WaterMiser drains the existing water in the cooler to allow it to be replaced with fresh water only when it is needed Therefore you may notice your cooler draining water occasionally How often the WaterMiser performs this operation depends upon the quality of the water supply and the rate of evaporation In areas of poor water quality the WaterMiser...

Page 10: ...ge HEALTH REGULATIONS In some regions regulations require that evaporative air coolers be serviced at specific intervals MAINTENANCE WARNING As your cooler is mounted on the roof we suggest that any maintenance or checks be carried out by an authorised Seeley International dealer or service agent Climbing onto the roof can be hazardous and could result in injury to you and damage to your property ...

Page 11: ...e water distributing spreader tray channels under the lid 5 Drain the tank 6 Thoroughly clean the tank pump filter and salinity probe if fitted 7 If a bleed funnel is fitted remove it from the tank as shown below Keep the O Ring in a safe place for later use 1 ILL2144 A 2 1 ILL2144 A ACCESS FOR SERVICING AND MAINTENANCE The cooler should be installed in a position that allows adequate access for i...

Page 12: ... pads that vary from the standard 90mm thickness While removing the pad frames take note of the location each belongs to Check for stickers indicating correct locations for thick or cut edge pads Stickers adhered to the fan scroll indicate the correct position If fitted incorrectly they may cause problems Thicker pads may catch on internal components causing damage Thicker pads may impede the corr...

Page 13: ...quired Drain Valve Bleed Funnel operation Component Function Pump operation Drain Valve operation Motor Operation Solenoid operation Wall Control operation General Operation Water Level Set Point Water Fill Time Water Drain Time Water Distribution across Pads Airflow through system Outlets General Product condition includes correct fitting of all components and items replace as required We require...

Page 14: ...for conditioned air Ensure sufficient exhaust openings Excessive ambient humidity On days during the summer when the ambient humidity is high the cooler will not reduce the temperature as much as on drier days Cooler turns ON and OFF Fault in the cooler Contact your Seeley International authorised dealer or service number If your controller prompts you to call a service agent please contact your l...

Page 15: ......

Page 16: ... introduce continual product improvement Accordingly specifications are subject to change without notice Please consult with your dealer to confirm the specifications of the model selected MANUFACTURED BY SEELEY INTERNATIONAL PTY LTD 112 O SULLIVAN BEACH RD LONSDALE SA 5160 AUSTRALIA IMPORTED BY SEELEY INTERNATIONAL EUROPE LTD UNIT 11 BYRON BUSINESS CENTRE DUKE STREET HUCKNALL NOTTINGHAM NG15 7HP ...