12
|
Installation of the cooler must conform to local electrical rules,
regulations and standards.
Important!
It is a requirement of Seeley International that all
coolers be connected to a dedicated circuit to the distribution
board, with a separate circuit breaker and incorporate means
to ensure all-pole disconnection from the supply mains, in
accordance with local and national wiring rules.
The following specifications for the cooler electrical supply are
required:1
TBQI5500 & TBQI7500: 115V / 60Hz
The electronics module is fitted with a 10A anti-surge fuse.
WARNING!
If the supply cord is damaged, it must be replaced
by the manufacturer, its service agent or similarly qualified
persons in order to avoid a hazard.
ELECTRICAL REQUIREMENTS
ILL3102-A
ELECTRICAL CONNECTION
Connect the motor cable to the base of the electronics module.
It is a polarised plug and will only insert one way. Ensure it is
secured fully so that its retention clips are engaged.
Route the end of the wall control cable out of the cavity via
the same channel as the motor cable. Ensure you have about
200mm (8”) of wall control cable outside the cavity.
With both cables in place (inside the channel), re-assemble the
electronics module and screw it to the pan (reservoir).
Important!
The isolation switch cannot be activated unless this
screw is fixed in place.
Switch OFF the electronics module before connecting any
accessories.
ILL496-C
ILL496-C
ILL1060-E
ILL1060-E
Note!
Fit either the shorting plug or water sensor as required.
DRAIN
MOTOR
CONTROL
WATER
PROBE
PUMP
SOLENOID
WALL CONTROL
DIAGNOSTIC
LEDS
FUSE
MAINS
CONNECTOR
MOTOR
866118-A
560885
REPLACEABLE FUSE LINK:3AG,10A,250V
ON
SPARE
SOCKET
/ LINK
ILL2119-B
PUMP
MOTOR
ILL2119-B
MAIN POWER SUPPLY